Vinicius Ishimine
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2002
Directeur
Jury
Oliveira, Everton de (Président)
Chang, Hung Kiang
Sígolo, Joel Barbujiani
Titre en portugais
Avaliação hidrogeológica e hidrogeoquímica em área contaminada por manganês na região de Suzano - SP
Mots-clés en portugais
Geoquímica
Hidrogeologia
Poluição da água
Resumé en portugais
A prática antiga de disposição de resíduos de óxido de manganês em valas sem impermeabilização permitiu a contaminação de solo e água subterrânea por manganês em uma área em Suzano, São Paulo. No local, foram mapeadas duas fontes de contaminação, a principal delas encontra-se enterrada em terreno adjacente à área da indústria, e a secundária, que não foi formada por disposição voluntária de resíduo no solo, encontra-se na área da indústria, como resultado de deposição de material particulado liberado durante o manuseio do produto. Testes de condutividade hidráulica 'in situ' apresentaram valores de K na ordem de '10 POT. -7' m/s. A velocidade da água subterrânea encontra-se no intervalo entre 0,33 e 17,26 cm/dia. Os resultados analíticos nas amostras de água subterrânea indicaram presença de manganês com valores acima dos limites estabelecidos pela Portaria 1469 do Ministério da Saúde na maioria dos poços de monitoramento (Valor Máximo Permitido, 0,10 mg/L), alcançando valores máximos de 6.800 mg/L no primeiro evento de monitoramento (outubro/98) e 4.876 mg/L no segundo (abril/99). Amostras de solo da porção jusante da área indicaram concentrações elevadas de manganês, atingindo valores de até 41.000 mg/Kg. O mapeamento da pluma de contaminação de água subterrânea mostra que ela está inserida em parte do terreno ocupado pela área em estudo e quase que a totalidade da porção jusante a este (área alagadiça). A modelagem hidrogeoquímica realizada através do programa Wateq4f apresentou supersaturação de hidróxido de ferro na maioria das amostras indicando que muitos metais podem estar adsorvidos neste complexo. Muitas amostras indicaram presença de sulfato de manganês, MnS'O IND. 4 POT. 0' (aq). Devido às altas concentrações de manganês encontradas em solo e água subterrânea, recomenda-se a execução de ações corretivas, uma vez que o local encontra-se inserido numa Área de Proteção de Mananciais.
Titre en anglais
Not available.
Mots-clés en anglais
Not available.
Resumé en anglais
The past practice of burying waste of manganese oxide in open, unprepared ditches in an industrial site in Suzano, São Paulo, has originated soil and groundwater contamination. Two sources of contamination were mapped at the site and its neighbourhood. The main source was placed as buried waste on a property adjacent to the industrial área. A second source was originated from dust coming from handling material at the industry. In situ hydraulic conductvty tests indicated K on the order of '10 IND. -7' m/s and 17,26 cm/dia. Chemical analyses from groundwater samples indicated manganese concentration above Brazilian standards in most monitoring wells (Portaria 1469 of the Ministerio da Saúde - Valor Máximo Permitido, 0,10 mg/L). The highest manganese concentration were 6.800 mg/L in the first sampling round and 4.876 mg/L in the second. Soil samples from the downgradient portion of the area also indicated high manganese concentrations, with values as high as 41.000 mg/Kg. The mapping of the groundwater contamination plume shows only a small portion of it within the limits of the industry site. Most of plume lies downgradient of the site, in the wetlands. The hydrogeochemical modeling using Wateq4f indicated a supersaturation of iron hydroxide in most groundwater samples, which indicates that many metals might be adsorbed into these complexes. Many samples indicated the presence of manganese sulphate, 'MnSO IND. 4 POT. 0' (aq). Due to the very high concentration of manganese found in the area, it is recommended a corrective action for soil and groundwater, since the site is located within an Environment Protection Area (Área de Proteção de Mananciais).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Ishimine__Mestrado.pdf (10.75 Mbytes)
Date de Publication
2015-11-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.