Doctoral Thesis
DOI
https://doi.org/10.11606/T.43.2011.tde-30092011-174532
Document
Author
Full name
Tiago Fiorini da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Martins, Marcos Nogueira (President)
Added, Nemitala
Galvao, Ricardo Magnus Osorio
Lin, Liu
Sciani, Valdir
Title in Portuguese
Sistema de monitoramento de feixe baseado em radiação óptica de transição (ROT)
Keywords in Portuguese
Acelerador de partículas.
Física nuclear
Instrumentação (Física)
Radiação eletromagnética
Abstract in Portuguese
Quando uma partícula carregada em movimento uniforme cruza a superfície entre dois meios de propriedades eletromagnéticas diferentes, ela emite a chamada Radiação de Transição (RT). Esta radiação tem espectro amplo, com emissão inclusive no intervalo de radiação visível. Esse processo de produção de radiação tem sido muito empregado em sistemas de monitoramento de feixes em aceleradores de partículas, por ser um processo que responde linearmente à carga que cruza a superfície e por permitir o monitoramento de diversos parâmetros do feixe em um único ponto de observação. Neste trabalho é apresentado o desenvolvimento de um sistema de monitoramento baseado em RT no intervalo óptico para operar em baixas energias de feixe de elétrons (próximas de 2 MeV) e realizar o diagnóstico de parâmetros importantes do feixe na entrada do primeiro estágio de aceleração do Mícrotron do IFUSP.
Title in English
Beam diagnostic device based on Optical Transition Radiation (OTR)
Keywords in English
Electromagnetic radiation
Instrumentation (Physics)
Nuclear physics
Particle accelerators
Abstract in English
Transition Radiation (TR) is emitted when a charged particle moving with constant velocity, crosses the boundary between two media with different electromagnetic properties. This radiation is emitted in an wide spectral range, including the optical interval. This physical process has been used in beam diagnostic devices in particle accelerators due to its linear response to the charge that crosses the boundary and also because it allows the measurement of several beam parameters in a single observation point. In this work, we present the design of a device based on TR in the optical range to operate with low energy beams (about 2 MeV). The device enables the determination of the transverse phase space and of the fractional momentum deviation of the beam at the end of the linac, allowing the determination of important beam parameters at the entrance to the Microtron Booster.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
thesisTFS.pdf (8.15 Mbytes)
Publishing Date
2011-11-18
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • SILVA, T. F., et al. Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators [doi:10.1063/1.4748519]. Review of Scientific Instruments [online], 2012, vol. 83, n. 9, p. 093301.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.