Disertación de Maestría
DOI
https://doi.org/10.11606/D.43.2011.tde-26042012-152350
Documento
Autor
Nombre completo
Bernardo José Braga Batista
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Yoshimura, Elisabeth Mateus (Presidente)
Baffa Filho, Oswaldo
Maidana, Nora Lia
Título en portugués
Avaliação de dosímetros termoluminescentes para uso em radioterapia com fótons de alta energia
Palabras clave en portugués
Dosimetria
Radioterapia
Termoluminescência
Resumen en portugués
Atualmente a maior parte dos tratamentos radioterápicos é feita através de irradiações com feixes de fótons de alta energia. Esses feixes se originam em fontes radioativas (de nuclídeos como o cobalto 60) ou são gerados em aceleradores lineares de elétrons. Para as medidas dosimétricas nesses feixes, uma das técnicas mais utilizada é a termoluminescência (TL) e, para a correta utilização dos dosímetros termoluminescentes (TLDs), é necessário conhecer suas características dosimétricas como, por exemplo, a variação da sua resposta com a energia do feixe de radiação. O objetivo desse trabalho foi estudar essa dependência energética da resposta TL de diversos materiais quando irradiados em feixes de fótons de alta energia. Para isso, foram obtidas curvas de resposta TL em função da dose absorvida em água para os LDs de LiF:Mg, Ti (TLD-100), fluorita natural brasileira, CaSO4:Dy, Mg2SiO4:Tb e l2O3:C irradiados em feixes gama de 60Co e de raios X de aceleradores lineares com potenciais de aceleração nominais de 6, 10, 15 e 18 MV. O estudo foi feito em uma faixa de doses equivalente à utilizada em fracionamentos padrão de tratamentos de radioterapia e os resultados demonstram que, nessas condições, não há variação maior que 3% na resposta TL em função da energia dos fótons. A relação entre a deposição e doses nos TLDs e a deposição de doses na água em função da variação da energia oi estudada por simulação de Monte Carlo (MC), através do código PENELOPE, e os resultados foram coerentes com os resultados experimentais. Os TLDs também foram irradiados com nêutrons térmicos e epitérmicos e apresentaram sensibilidade a esse tipo de radiação. No entanto, a coerência dos resultados experimentais e de MC (que não levaram em conta a presença de nêutrons), o estudo da variação da sensibilidade relativa com a energia e a análise das curvas de emissão dos TLDs levam à conclusão e que a influência na resposta TL devida a nêutrons que contaminam os feixes de fótons estudados, é desprezível para todos os materiais. Os resultados desse trabalho indicam que, para a faixa de doses e energias utilizadas rotineiramente na radioterapia, os TLDs de LiF:Mg, Ti (TLD-100), fluorita natural brasileira, CaSO4:Dy, Mg2SiO4:Tb e Al2O3:C podem ser utilizados sem a aplicação de fatores de correção para a energia do feixe.
Título en inglés
Evaluation of thermoluminescent dosimeters for using in radiotherapy with high energy photons
Palabras clave en inglés
Dosimetry
Radiotherapy
Thermoluminescence
Resumen en inglés
Currently the majority of radiotherapy treatments are done by irradiation with high energy photon beams. These beams are emitted by radioactive sources (of nuclides such as cobalt 60) or generated in electron linear accelerators. For dosimetric measurements on these beams, one of the most used techniques is the thermoluminescence (TL). For the correct use of the thermoluminescent dosimeters (TLDs), it is necessary to know their dosimetric properties like, for example, the variation of their response with the energy of the radiation beam. The purpose of this study was to assess the energy response of various TL materials when irradiated with high energy photon beams. So, curves relating the TL response and absorbed dose to water were obtained for LiF:Mg, Ti (TLD-100), Brazilian natural fluorite, CaSO4:Dy, g2SiO4:Tb and Al2O3:C TLDs irradiated with gamma rays from a 60Co source and linear accelerator X ray beams with nominal accelerating potential of 6, 10, 15 and 18 MV. The study was done in a dose range similar to that used in standard fractionated radiotherapy treatments and the results show that under these conditions, there is no variation larger than 3% in the TL response as a function of photon energy. The relationship between the dose deposition in the TLD and the dose deposition in water in function of the photon energy was studied by Monte Carlo method (MC), using the PENELOPE code system, and the results were consistent with the experimental outcomes. The TLDs were also irradiated with thermal and epithermal neutrons and proved to be sensitive to them. However, the consistency of the experimental and MC results (which did not take into account the presence of neutrons), the study of the variation in TL relative sensitivity with the beam energy, and the TLD glow curve shape analysis lead to the conclusion that the influence on TL response due to neutron contamination in the therapeutic photon beams is negligible for all materials. The results indicate that for the range of doses and energies used routinely in radiotherapy, the LiF:Mg, Ti (TLD-100), Brazilian natural fluorite, CaSO4:Dy, Mg2SiO4:Tb and Al2O3:C TLDs can be used without applying any correction factors for the beam energy.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-05-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores