Tesis Doctoral
DOI
https://doi.org/10.11606/T.43.2007.tde-26032008-102947
Documento
Autor
Nombre completo
Diogo Soga
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Figueiredo Neto, Antonio Martins (Presidente)
Brito, Giancarlo Esposito de Souza
Lyra, Marcelo Leite
Olmedo, Hugo Alejandro Gallardo
Rechenberg, Hercilio Rodolfo
Título en portugués
Estudo de propriedades não-lineares de colóides magnéticos nas escalas de tempo de mili e femtossegundos
Palabras clave en portugués
Escala de tempo de femtossegundos.
Ferrofluido
Física Óptica
Técnica de varredura-Z
Resumen en portugués
Neste trabalho, estudamos alguns colóides magnéticos dos tipos iônico e surfactado com partículas de estrutura tipo espinélio. Usamos a técnica de varredura-Z para investigar as amostras nas escalas de tempo de femtossegundos e milissegundos. Medimos o índice de refração não-linear nas duas escalas de tempo. Na escala de milissegundos todas as amostras apresentaram comportamento tipo lente divergente, e os valores obtidos são da ordem de 10^(-7) cm^2/W. Na escala de femtossegundos, as amostras iônicas apresentaram comportamento tipo lente convergente, com valores típicos do índice de refração não-linear da ordem de 10^(11) cm^2/W. Também medimos a absorção não-linear na escala de tempo de femtossegundos. Os valores obtidos são da ordem de 10^2 cm/GW. Com os dados obtidos na escala de femtossegundos calculamos a susceptibilidade elétrica de terceira ordem (chi(3)). O módulo de chi(3) encontrado é da ordem de 10^(-17) m^2/V^2 (ou 10^(-9) esu). Obtivemos evidências experimentais da contribuição da susceptibilidade elétrica de quinta-ordem nas medidas de absorção não-linear. Verificamos a presença do efeito de tamanho das partículas no valor de chi(3) ao estudar partículas de mesma composição e de diâmetros diferentes.
Título en inglés
Study of Nonlinear Properties of Magnetic Colloids in the Milli- and Femtosecond Time Scales.
Palabras clave en inglés
Femtosecond Time Scale.
Ferrofluid
Optical Physics
Z-Scan Technique
Resumen en inglés
In this work, we studied some magnetic colloids of kind ionic and surfacted with particles of spinel struture. We used the Z-Scan technique to investigate the samples in the time scales of femto- and milliseconds. We measured the nonlinear refractive index in both time scales. In the scale of milliseconds all samples showed divergent-lens-type behavior, and the obtained values are of order of 10^(-7) cm^2/W. In the femtoseconds scale, the ionic-type samples have convergent-lens-type behavior, with the typical values of order of 10^(11) cm^2/W. Also we measured the nonlinear absorption in the femtoseconds time scale. The obtained values are of order of 10^2 cm/GW. With the data obtained in the femtoseconds time scale we calculated the third-order electric susceptibilities (chi(3)). The found modulus of chi(3) is of order of 10^(-17) m^2/V^2 (or 10^(-9) esu). We obtained experimental evidences that fifth-order electric susceptibilities can contribute to the measurements of nonlinear absorption. We observed the dependence of particles' size effect in the values of chi(3) in the studies of particles of the same composition and different diameters.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
tese_dr_final.pdf (1.42 Mbytes)
Fecha de Publicación
2008-03-27
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • ESPINOSA, D. H. G., et al. Investigation of the optical absorption of a magnetic colloid from the thermal to the electronic time-scale regime: measurement of the free-carrier absorption cross-section [doi:10.1364/JOSAB.29.000280]. Journal of the Optical Society of America. B, Optical physics [online], 2012, vol. 29, p. 280-285.
  • L. F. Gamarra, et al. Characterization of the biocompatible magnetic colloid on the basis of Fe3O4 nanoparticles coated with dextran, used as contrast agent in magnetic resonance imaging [doi:10.1166/jnn.2010.2200]. Journal of Nanoscience and Nanotechnology [online], 2010, vol. 10, p. 4145-4153.
  • SOGA, Diogo, et al. Nonlinear optical properties of ionic magnetic colloids in the femto and milliseconds time scales: change from convergent-to-divergent lens-type behaviors [doi:10.1364/JOSAB.24.000049]. Journal of the Optical Society of America. B, Optical physics [online], 2007, vol. 24, p. 49-55.
Todos los derechos de la tesis/disertación pertenecen a los autores