• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.43.2004.tde-24022014-151850
Document
Author
Full name
José Gabriel Aguirre Gómez
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2004
Supervisor
Committee
Nussenzveig, Paulo Alberto (President)
Barata, Joao Carlos Alves
Dechoum, Kaled
Martinez, Maria Aparecida Gonçalves
Padua, Sebastiao Jose Nascimento de
Title in Portuguese
Correlações e ruído de intensidade e de fase em transparência induzida eletromagneticamente: experimentos e teorias
Keywords in Portuguese
Eletromagnetismo
Feixes ópticos
Física óptica
Abstract in Portuguese
Neste trabalho apresentamos resultados experimentais e teóricos do ruído de intensidade e de fase, e das correspondentes correlações, entre os campos de bombeio e sonda na transparência induzida eletromagneticamente. Experimentalmente, nessa condição, medimos excesso de ruído de intensidade em ambos feixes e correlação e anti-correlação de ruído de intensidade, mostrando claramente que elas dependem tanto da intensidade dos feixes, quanto da frequência de análise em que as medidas são realizadas. Utilizando uma varredura local do feixe sonda, observamos estruturas no espectro de ruído dos campos na transparência induzida e, a partir do ruído da soma e da diferença das intensidades dos feixes, vimos que nessa região há zonas com correlação e anti-correlação de intensidade, intercaladas. Estas estruturas dependem, novamente, da intensidade dos feixes e da frequência de análise. Ainda no campo experimental, com relação ao ruído de fase, medimos excesso de ruído nos nossos feixes e, pela primeira vez, medimos uma correlação desse ruído entre os feixes na condição de transparência induzida. Teoricamente, aprofundamos análises realizadas com um modelo em que átomos e campos são tratados quanticamente e, dadas as limitações constatadas, desenvolvemos um novo modelo semi-clássico. As novas previsões obtidas com esse modelo, em que os campos possuem fases difusivas, mostram um bom acordo qualitativo com os resultados experimentais. O excesso de ruído de intensidade dos feixes, observado na transparência induzida, se deve ao excesso de ruído de fase dos lasers, que é transferido ressonantemente pelos átomos para o ruído de intensidade.
Title in English
Correlations Intensity Noise Electromagnetically Induced Transparency Stage Experiments Theory
Keywords in English
Eletromagnetism
Optical beams
Physical optics
Abstract in English
In this work we present experimental and theoretical results of intensity and phase noise, and of the correspondent correlations, between pump and probe fields in electromagnetically induced transparency. Experimentally, in this condition, we measure intensity excess-noise in both beams as well as intensity correlations and anti-correlations, clearly showing that both are dependent on the fields intensities and on the analysis frequency. We also observed structures in the noise spectra of the fields in the induced transparency and that, in a single spectrum, there are zones with correlation and anti-correlation of intensity, interchanged. These structures are dependent, again, on the fields intensities and on the analysis frequency. We also measured excess phase noise in our beams and, for the first time, we measured a phase noise correlation between the beams in the condition of induced transparency. Theoretically, we further developed an analysis with a model in which the atoms and the fields are treated quantum-mechanically. Owing to limitations detected in the application of this model to our experimental situation, we developed a new semi-classical model, in which the fields present phase diffusion. The new predictions obtained show a good qualitative agreement with the experimental result features. The excess noise of intensity of the beams, in the electromagnetically induced transparency, is a result of the resonant transfer of the diode lasers excess phase noise into intensity noise by interaction with the atoms.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
42555Gomez.pdf (5.80 Mbytes)
Publishing Date
2014-02-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.