Autor
Nombre completo
Suene Bernardes dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Tabacniks, Manfredo Harri (Presidente)
Yoshimura, Elisabeth Mateus
Zamboni, Cibele Bugno
Título en portugués
Elementos traço em soro sanguíneo medidos pelos métodos PIXE e ICP-MS
Palabras clave en portugués
Elementos traço
ICP
PIXE
Soro
Resumen en portugués
O principal objetivo deste trabalho foi desenvolver uma metodologia de análise de soro sanguíneo utilizando os métodos Proton Induced X-ray Emission (PIXE) e Inductively Coupled Plasma Mass Spectrometry (ICP-MS). O PIXE é um método de análise multielementar baseado na detecção dos raios-X característicos emitidos pelas amostras, quando bombardeadas com feixes de íons (H+, He+, ...) com energia da ordem de alguns MeV. Já o ICP-MS é um espectrômetro de massa que analisa componentes de amostras ionizadas, separados de acordo com suas razões massa carga (m/z). Para a realização deste estudo, as amostras de sangue dos voluntários (30 jovens com idade entre 18 e 25 anos) foram coletadas no Hospital Universitário da USP utilizando tubos de vidro da BD VacutainerTM sem aditivos (Processo do Comitê de Ética: HU-615/05). O soro foi obtido pela centrifugação dos tubos a 3000 rpm. As amostras foram pipetadas sobre Nuclepore (10?m de espessura) e secas a temperatura ambiente, para o método PIXE, e diluídas de 1:10, para as análises com ICP-MS. A acurácia dos resultados foi verificada analisando materiais de referências de soro do National Institute of Public Health - Québec (ICP-03B-02 e ICP-02-S-05). A análise dos padrões apresentou 78% dos dados entre ±1?, 14% entre ±2? e 4% além de ±3?. Este estudo de elementos traço em soro humano revelou um total de 22 elementos: Be, Al, P, S, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Br, Mo, Cd, Sn, Tl e Pb, com concentrações entre 9 ng/l e 6 g/l, o que compreende 9 ordens de grandeza, e também permitiu o estudo das funções de distribuição de probabilidades dos elementos. As técnicas utilizadas foram eficientes e complementares na realização deste trabalho. Os resultados das concentrações elementares medidas neste trabalho concordaram com os valores da literatura.
Título en inglés
Trace elements in serum measured by PIXE and ICP-MS
Palabras clave en inglés
ICP-MS
PIXE
serum
Trace elements
Resumen en inglés
The main objective of this work was to develop a methodology for the analysis of blood serum by Proton Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). PIXE is a multi elementary spectrometric method that relies on the detection of characteristics X-rays emitted by a sample bombarded with an energetic (~MeV) ion beam (H+, He+, ...). With the ICP-MS one measures the elementary components in an ionised sample, separated according to their mass to charge ratio (m/z). For this study, the blood samples were collected from 30 young healthy adult volunteers with age between 18 and 25 years, in the University Hospital using additiveless BD VacutainerTM tubes (Authorisation agreement HU-615/05). Blood serum was obtained by centrifugation of the tubes at 3000 rpm. For PIXE analysis, the serum samples were pipetted on Nuclepore film (10?m thick) and dried at room temperature. For the ICP-MS analysis, the serum samples were diluted 1:10. Accuracy of both methods was obtained analysing serum reference materials supplied by the National Institute of Public Health - Québec (ICP-03B-02 and ICP-02-S-05). The analysis of the reference materials presented results for the elementary concentrations within ±1? for 78% of the data, 14% of the data lied within ±1? and ±2?, and 4% above ±3?. The analysis of trace elements in human blood serum by PIXE and ICP-MS revealed a total of 22 elements, ranging over 9 orders of magnitude: Be, Al, P, S, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Br, Mo, Cd, Sn, Tl e Pb, with concentrations between 9 ng/l and 6 g/l. The PIXE and ICP-MS techniques were efficient and complimentary for the accomplishment of this work. The elementary concentrations measured in this work agreed with overall data in literature.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Tese_suene_2007.pdf (1.98 Mbytes)
Fecha de Publicación
2007-09-11
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.