• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.43.2005.tde-14112013-142009
Documento
Autor
Nome completo
Valdemar Bellintani Junior
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2005
Orientador
Banca examinadora
Galvao, Ricardo Magnus Osorio (Presidente)
Machida, Munemasa
Roberto, Marisa
Ueda, Mario
Vannucci, Alvaro
Título em português
Diagnóstico bolométrico no TCABR
Palavras-chave em português
Física de plasma
Radiação (energia radiante)
Sensores óticos
Tokamaks
Resumo em português
Foi projetado, construído e instalado um sistema bolométrico para a análise das descargas de plasma do TCABR. Este sistema possibilita a observação da coluna de plasma através de cordas caracterizadas por diferentes direções e ângulos. Os bolômetros utilizados são fotodiodos especiais, acondicionados em câmeras dotadas de colimadores para observação do plasma. A faixa espectral da sensibilidade dos fotodiôdos abrange desde o visível até a região de raios-X moles, energia de fótons desde 7 eV até 6.000 eV. Para este diagnóstico, foi construída uma eletrônica específica para amplificação dos sinais bolométricos. A resolução temporal do diagnóstico é de 3 ms devido a interferência gerada pelo tokamak. Com este sistema, foi obtido pela primeira vez no TCABR, o perfil da potência emitida pela coluna de plasma, sendo este o principal resultado deste trabalho. Para isto, foi desenvolvido um programa destinado a inverter os dados bolométricos utilizando como princípio o método de Abel. Uma série de descargas ôhmicas ( 0,9 X "10 POT.19" < ne < 2,0 X 10 POT.19" "m POT.3" e 67 < "I IND.p" < 100 kA) foram estudadas com o diagnóstico. Obteve-se para o volume da coluna uma fração Prad/Poh não maior que 30%, valor semelhante ao obtido para o tokamak TCA. Observou-se também diferenças acentuadas para o perfil de potência emitido por descargas com baixos e altos valores da corrente de plasma. Estas diferenças são atribuídas principalmente ao aumento da temperatura eletrônica. A concentração de impurezas metálicas foi calculada no eixo da coluna, obtendo-se valores entre 0,9-1,2 X "10 POT.17" "m POT.-3"
Título em inglês
Bolometric diagnosis in the TCABR
Palavras-chave em inglês
Optical Sensors
Physics of plasmas
Radiation (radiant energy)
Tokamaks
Resumo em inglês
In this work, a bolometric diagnostic system was projected, built and installed in the TCABR tokamak, in order to measure the total power radiation loss from the plasma. The system allows plasma observation through 27 lines of sight with different directions and angles. The detector used was a silicon p-n junction photodiode array, for applications in the vacuum ultraviolet and the soft x-ray (XUV, energy range 7 eV to 6 keV) spectral region. An electronic system for amplification of the bolometer signal was also projected and built. This system was projected taking into account the strong electromagnetic noise due to the tokamak operation. Using this bolometric system, the shape of the emitted power was obtained for the first time in the TCABR, and this is the main result of this work. To deal with the bolometric data, we developed a program based on the Abel inversion. A serie of ohmic discharges were studied with this diagnostic. The value of the Prad/Poh obtained for this serie was below 30%, in agreement with the old TCA data. The shape for discharges with high and low plasma current were also analyzed. We find a big difference in the two cases, showing the effect of electron temperature change. The metallic impurity density on axis were calculated using the value of Prad(0) experimentally obtained. For the serie of discharges analyzed, this value remained between 0,9-1,2 X "10 POT.17" "m POT.-3"
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2013-12-17
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.