Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.43.2013.tde-13102014-194554
Documento
Autor
Nome completo
Marcia Tiemi Saito
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2013
Orientador
Banca examinadora
Yoshimura, Elisabeth Mateus (Presidente)
Lino, Antonio Carlos Loureiro
Muramatsu, Mikiya
Título em português
Utilização de técnicas de análise de franjas para a avaliação de dimensões de lesões na pele
Palavras-chave em português
deslocamento de fase
dimensões de lesões
lesões na pele
Projeção de franjas
Resumo em português
A medida precisa de dimensões de lesões crônicas e o acompanhamento do processo de cicatrização são essenciais durante o tratamento. Porém, os métodos utilizados atualmente para esse fim são invasivos e imprecisos. Por outro lado, as técnicas de análise de franjas são métodos óticos amplamente explorados para a obtenção de topografias de objetos, pela análise da deformação de um padrão periódico de franjas projetado sobre a superfície deles. Dessa forma, a utilização dessas técnicas surge como uma interessante alternativa para a obtenção da topografia e das dimensões das lesões. Com o intuito de desenvolver uma técnica de análise de franjas capaz de medir dimensões de lesões na pele de forma não invasiva, rápida, exata e de baixo custo, comparou-se a Técnica Moiré de Projeção e a Técnica de Projeção de Franjas, chegando-se a conclusão de que a segunda era a mais adequada para o propósito. Assim, projetaram-se quatro padrões de franjas, deslocados de ¼ do período entre si, sobre a superfície do objeto de estudo e, através da análise das imagens, obteve-se um mapa com as fases dos padrões moduladas pela presença do objeto. Em seguida, esse mapa foi desmodulado para a obtenção das fases reais. Para a calibração desse mapa e obtenção das dimensões do objeto, utilizou-se um objeto de calibração de dimensões conhecidas, cujas imagens foram obtidas e analisadas nas mesmas condições que as imagens do objeto de estudo. Para a validação da técnica, obteve-se a topografia de vários objetos, que simulavam diferentes características das lesões, e compararam-se os resultados obtidos com as dimensões conhecidas deles. As limitações encontradas para a técnica se referem à presença de sombra e brilho na imagem e a variações abruptas na topografia dos objetos. A incerteza obtida para a técnica com o arranjo experimental utilizado foi de 3 mm. Uma vez validada a técnica e estudadas suas limitações, foram feitas medidas das dimensões de lesões em pacientes e verificou-se que é possível a utilização da técnica de análise de franjas para esse fim. Assim, pôde-se estabelecer uma sugestão de protocolo para a medição de dimensões de lesões no ambiente clínico, utilizando a análise de franjas.
Título em inglês
Utilization of fringe projection technique for evaluation of wound dimensions and of healing progress
Palavras-chave em inglês
Fringe projection
phase shift
wound dimensions
Resumo em inglês
Measuring chronic wound dimensions and evaluating the healing process are very important procedures during the treatment; however, the methods currently used for this are invasive and inaccurate. On the other hand, the fringe analysis techniques are optical methods, widely explored to obtain the 3D topography of an object. It consists in analyzing the deformation of a periodic fringe pattern projected on an object surface. Thereby, the fringe analysis techniques are an interesting alternative to obtain wound dimensions and topography. In order to develop a fringe analysis technique that can measure wound dimensions using a non-invasive, fast, accurate and low-cost method, the Moiré Projection and the Fringe Projection Techniques were compared, with the conclusion that the second one was the most suitable for the proposal. This way, four fringe patterns are projected on the object surface, each one displaced of ¼ of the period. Through the images analysis, a wrapped phase map, with the phases modulated by the object topography, was obtained. This map is unwrapped to obtain the actual phases. To calibrate this map and obtain the object dimensions, a calibration object with known dimensions was used. Its images were obtained and analyzed in the same conditions as the studied object. To validate the technique, the topography of different objects, which simulated wound characteristics, were obtained, and the results were compared with the known dimensions. The limitations of this technique are due to the presence of shadow and bright light in the image and to abrupt variations in the object topographies. The uncertainty of the technique obtained with this experimental setup was of 3 mm. Once the technique was validated and its limitations were studied, measurements of patients wound dimensions were made and it was verified that the utilization of the fringe analysis technique for this application is feasible. Thus, it was possible to develop a suggestion of procedure protocol to use the technique for measuring wound dimensions in the clinic environment.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2014-10-14
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • Sousa, M V P, et al. Light distribution in phantoms. In International Conference on Medical Physics, Porto Alegre, 2011. Proceedings of the International Conference on Medical Physics., 2011. Abstract.
  • Sousa, M V P, et al. Phantoms of fingers with various tones of skin for LLLT dosimetry. In SPIE PHOTONICS WEST BIOS, 2011, SAN FRANCISCO, 2011. SPIE PROCEEDINGS. : Society of Photo-Optical Instrumentation Engineers (SPIE)., 2011.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.