Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.43.2006.tde-12062015-163509
Document
Auteur
Nom complet
Viviane Silva Poli Tanaka
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Tabacniks, Manfredo Harri (Président)
Martins, Marcos Nogueira
Salvador, Vera Lucia Ribeiro
Titre en portugais
Análise elementar sub-ppb de amostras líquidas pelos métodos PIXE e TXRF
Mots-clés en portugais
Aceleração de partículas
Física nuclear
Resumé en portugais
O principal objetivo desse trabalho foi investigar a possibilidade da detecção sub-ppb (10-9 g/g) de elementos químicos presentes em amostras líquidas, analisadas por meio da espectrometria de raios-X, seja por STXRF (Synchrotron Total reflection X-ray Fluorescence), ou PIXE (Particle Induced X-ray Emission). Na ausência de padrões certificados, foram preparados em laboratório padrões líquidos multielementares com concentrações variando de 1 a 20 ppm, posteriormente micropipetados sobre substrato de Lucite, constituindo assim amostras adequadas para análises STXRF. Visando controlar a manipulação volumétrica, foi utilizado como padrão interno ítrio, em função do qual foi determinada a curva de sensibilidade relativa para o método. Após pré-concentração das amostras, estas foram micropipetadas sobre substratos de Lucite, Mylar e Kimfoil e as análises foram realizadas no Laboratório Nacional de Luz Síncontron LNLS, em Campinas, SP e no Laboratório de Análise de Materiais por feixes Iônicos LAMFI, no IFUSP. Os limites de detecção para ambos os métodos foram determinados e comparados. Como esperado, a STXRF apresenta limites de detecção uma ordem de grandeza inferior ao PIXE para elementos com 20
Titre en anglais
Analysis sub-ppb of liquid samples by PIXE and STXRF methods
Mots-clés en anglais
Acceleration of particles
nuclear physics
Resumé en anglais
The main goal of this work was to investigate the feasibility of sub-ppb (10-9 g/g) detection of trace elements in liquid samples analyzed by STXRF (Synchrotron Total reflection X-ray Fluorescence) and by PIXE (Particle Induced X-ray Emission). For STXRF calibration, and due to the absence of certified liquid standards, a set of multielementary liquid standards was prepared in house, with concentrations varying from 1 to 20 ppm in water, and then micro-pipetted on regular 30 mm diameter Lucite discs. Ytrium was used as an internal standard and the relative sensitivity curves were found relative to it. Real water samples for trace element analysis, were first preconcentrated (to a factor of 5) and then micropipetted on Lucite and also on Lylar and Kimfoil thin films. All the STRXF and PIXE analysis were made respectively in the Laboratório Nacional de Luz Síncrotron LNLS , in Campinas, SP, and in the Laboratório de Análise de Materiais por feixes Iônicos LAMFI, USP. As expected, the minimum elementary detection limits for STXRF for elements with 20
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Tanaka_2006.pdf (6.11 Mbytes)