Disertación de Maestría
DOI
https://doi.org/10.11606/D.43.2000.tde-07082009-161526
Documento
Autor
Nombre completo
Carla da Costa Guimarães
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2000
Director
Tribunal
Okuno, Emico (Presidente)
Anjos, Roberto Meigikos dos
Herdade, Silvio Bruni
Título en portugués
Implementação de Grandezas Operacionais na Monitoração Individual e de Área
Palabras clave en portugués
Dosimetria
Grandezas Operacionais
monitoração de área
Monitoração individual
termoluminescência
Resumen en portugués
Neste trabalho implementamos as grandezas operacionais no sistema de monitoração de área e individual. Determinamos a combinação ideal dos detectores termoluminescentes para constituírem os monitores de radiação como sendo: dois de fluoreto de cálcio (CaF2), um envolto em filtro de chumbo de (0,50 ± 0,05) mm e outro sem filtro e um de fluoreto de lítio TLD-100, também sem filtro. Aproveitamos a propriedade termoluminescente desses detectores, qual seja a de emissão de luz em intensidade proporcional à dose de radiação recebida, quando eles são aquecidos. A grandeza final avaliada é o equivalente de dose ambiental H*(10) e direcional H(10,) para fins de monitoração de área e o equivalente de dose pessoal Hp(10) para monitoração individual. Para tanto, estudos foram realizados irradiando os monitores no ar no primeiro caso e na frente de um fantoma de PMMA preenchido com água no segundo caso. Para avaliar o desempenho dos monitores de radiação eles foram submetidos a testes de linearidade da resposta com a dose, dependência angular e dependência energética. Uma análise detalhada dos resultados obtidos mostrou que todos os valores dos equivalentes de dose obtidos em testes de desempenho estão dentro dos limites estabelecidos por normas internacionais, com 95% de nível de confiança. Para o monitor escolhido obtivemos para a razão [H(10)determinado/H(10)nominal ± desvio] no caso de equivalente de dose ambiental e pessoal respectivamente os valores: (1,02 ± 0,11) e (0,97 ± 0,25). Os desvios foram calculados com o método t de student, considerando o intervalo que contém o valor nominal com 95% de probabilidade.
Título en inglés
Implementation of new operational quantities in the Individual and area monitoring
Palabras clave en inglés
Area monitoring
dosimetry
Individual monitoring
operational quantities
Thermoluminescence
Resumen en inglés
Operational quantities have been implemented to be applied in individual and area routine monitoring against external radiation exposure. This procedure is based on the use of an ideal combination of thermoluminescent detectors inside a monitor: two pellets of CaF2, one covered by a lead filter of (0,50 ± 0,05) mm and another one without filter and one TLD-100 without filter too. The operational quantities studied for area monitoring are the ambient and directional dose equivalent, H*(10) and H(10,), respectively and for individual monitoring, the personal dose equivalent, Hp(10). To evaluate the personal dose equivalent, all the experiments were performed irradiating the monitor on a slab water phantom made of PMMA walls with outer dimensions 30x30x15 cm, (a substitute of ICRU sphere four-element tissue phantom) completely full of water. Area monitors were irradiated in free air without any phantom. In general, an operational quantity H is determined from the basic physical quantity kerma free-in-air by means of conversion coefficients. The blind performance testing of monitors was performed after type testing, including analysis of the linearity of the response with the dose, the angular and energy dependence. The results of these investigations agree with the values recommended by international organisations within 95 % of confidence level. The ratios (H(10)evaluated/H(10)nominal ± deviation) obtained for ambient and personal dose equivalente are respectively (1,02 ± 0,11) and (0,97 ± 0,25), with the monitor above quoted. The error was estimated with the method of t-student, considering 95 % confidence level.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-08-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.