Disertación de Maestría
DOI
https://doi.org/10.11606/D.43.2007.tde-02082007-161833
Documento
Autor
Nombre completo
Daniel Alexandre Baptista Bonifacio
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Moralles, Mauricio (Presidente)
Yoriyaz, Hélio
Yoshimura, Elisabeth Mateus
Título en portugués
Validação do Geant4 para a produção e detecção de raios X na faixa de energia de radiodiagnóstico
Palabras clave en portugués
Espectroscopia de raios X
Física médica
Método de Monte Carlo
Produção de raios X.
Resumen en portugués
Este trabalho teve como objetivo validar uma ferramenta computacional para a realização de simulações da interação de elétrons e da radiação X com a matéria, utilizando o método de Monte Carlo para possíveis estudos em radiologia diagnóstica. Para esse propósito, foi desenvolvido um programa computacional que simula a produção de radiação de um equipamento de raios X, com a finalidade de obter a distribuição de energia dos fótons que alcançam uma determinada região de interesse, sem a necessidade de medições experimentais. Outra tarefa realizada neste trabalho foi o cálculo da resposta de um detector do tipo CdTe, para possibilitar a correção de espectros medidos com esse detector em experimentos na faixa de energia de radiodiagnóstico. A ferramenta computacional escolhida para essas aplicações foi o Geant4, que é um conjunto de programas de distribuição livre relativamente novo e que é utilizado para simulações da interação da radiação com a matéria. Um dos principais diferenciais do Geant4 é o emprego da tecnologia de programação orientada a objetos e de técnicas avançadas de engenharia de software. Os resultados da etapa de simulação de espectros de energia produzidos por um equipamento de raios X mostram que o Geant4 pode ser utilizado para esta aplicação, mas com ressalvas na simulação de espectros de raios X com alvos com molibdênio para a região de mamografia, que é a situação onde as diferenças dos rendimentos de raios X característicos dos espectros simulados com os seus respectivos espectros de referência são maiores. Na etapa de simulação da detecção da radiação X por um detector do tipo CdTe são apresentados resultados com excelente acordo com os dados de referência. As diferenças encontradas devem ser mais influenciadas pelos efeitos de armadilhamento de cargas e do comportamento do campo elétrico no interior do cristal do detector, que são específicos para este detector e não fazem parte dos modelos físicos fornecidos pelo Geant4. Desta forma, a validação do Geant4 realizada neste trabalho mostrou algumas das possibilidades de uso desta versátil ferramenta na área de radiologia diagóstica.
Título en inglés
Validation of Geant4 for X-ray production and detection in the radiodiagnostic energy range
Palabras clave en inglés
Medical physics
Monte Carlo method
X-ray production
X-ray spectroscopy.
Resumen en inglés
The aim of this work was the validation of a computational tool applied in simulations of electrons and X ray interactions with matter, using the Monte Carlo method for possible studies in diagnostic radiology. To perform this task, a computational program was developed to simulate the radiation production of a X ray equipment, with the purpose of obtaining the photon energy distribution which comprehends the region of interest, without the necessity of experimental measurements. Another task carried through in this work was the calculation of a CdTe detector response, which was used in the correction of measured spectra with energy distribution typically found in diagnostic radiology. The employed computational tool was Geant4, which is a free distribution set of computational programs used for simulation of the passage of particles through matter. One of the main differentials of Geant4 is the exploitation of advanced software-engineering techniques and object-oriented technology. The results of the simulation of energy spectra produced by a X ray equipment show that Geant4 can be used for this application, but with restrictions concerning the simulation of X ray spectra from molybdenum targets in the mammography energy range. This is the situation where the differences of the characteristic X ray yield between the simulated and reference spectra are more pronounced. For the simulation of X ray measurements with a CdTe detector, the results showed excellent agreement with the reference data. In this case the discrepancies must be originated mainly by effects of charge trapping and the nonuniformity of the electric field inside the CdTe crystal. In resume, the validation of the Geant4 carried through in this work showed some of the possibilities for the use of this versatile tool in diagnostic radiology.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-09-11
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • MORALLES, M, et al. Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors [doi:10.1016/j.nima.2007.05.147]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detector [online], 2007, vol. 580, n. 1, p. 270-273.
  • MORALLES, Maurício, et al. Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit [doi:10.1063/1.3157829]. In AIP Conference Proceedings [online], São Sebastião, São Paulo, . São Sebastião, São Paulo : AIP, 2009. p. 51-56.