• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.43.2011.tde-02052012-102802
Documento
Autor
Nome completo
Fabio da Silva Bortoli
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2011
Orientador
Banca examinadora
Frajuca, Carlos (Presidente)
Barbosa, Eduardo Acedo
Caldas, Ibere Luiz
Fernandes, Almir
Passos, Emerson Jose Veloso de
Título em português
Sistemas vibracionais do detector de ondas gravitacionais Mário Schenberg.
Palavras-chave em português
Detetores
Instrumentação (astronomia)
Método dos elementos finitos.
Ondas gravitacionais
Vibrações
Resumo em português
O detector de ondas gravitacionais Mário Schenberg consiste de uma massa ressonante esférica de Cu(94%)Al(6%) com 65cm de diâmetro, pesando aproximadamente 1,15T, com um Q mecânico da ordem de 106 e todos os sistemas que possibilitam o seu funcionamento como detector de ondas gravitacionais. O projeto do detector prevê para este uma sensibilidade da ordem de 10-20 (em deformação). Para isso dependerá da eficiência dos sistemas vibracionais que utiliza. Neste trabalho os casadores mecânicos de impedância, foram simulados com um programa de elementos finitos e otimizados quanto à sua banda e acoplamento vibracional. Foi feita a análise do sistema de isolamento vibracional da nova suspensão, por meio da resposta em frequência do ruído sísmico na superfície da esfera, nos mesmos locais onde estão conectados os transdutores. Foi proposto um projeto novo para atenuar os ruídos provenientes do cabeamento que conduz os sinais de micro-ondas. Foi avaliado o efeito do ruído sísmico introduzido na suspensão e na esfera, também nos locais dos transdutores, utilizando este novo projeto. É apresentado um projeto para a conexão térmica do refrigerador por diluição, que a análise por simulação numérica demonstrou ser eficaz. A modelagem para análise vibracional é a melhor já feita para detectores esféricos, isto se comparada às que foram encontrados na literatura. Os resultados alcançados demonstraram que as atenuação em todos os sistemas analisados são adequadas às metas do projeto do detector Mário Schenberg, ou seja, os ruídos remanescentes estão abaixo do ruído térmico esperado na temperatura de 50mK.
Título em inglês
Vibrational systems of the Mario Schenberg gravitational wave detector.
Palavras-chave em inglês
Detectors
Finite element
Gravitational waves
Instrumental (astronomy)
Method.
Vibrations
Resumo em inglês
The Gravitational Wave detector Mario Schenberg consist of a spherical resonant-mass made of CuAl(6%) with 65 cm diameter e weighting 1.15 Ton, with a Mechanical quality factor of about 106 and all the systems that allows it to word as a gravitational wave detector. The detector design was made for it to reach a sensitivity of 10-20 (strain sensitivity). To reach this goal it depends on the efficiency of the it vibrational systems. In this work the transducers mechanical impedance matchers were simulated with a finite element program and optimized in its band and vibrational coupling. A analysis of the vibrational isolation of the new suspension was made by the frequency response of the seismic noise on the sphere surface, on the same places where they will be connected to the transducers. A new design for attenuation of the noise due to microwave cabling was proposed. The seismic noise introduced on the suspension and on the sphere was simulated using this new design. A design for the dilution refrigerator thermal connection is presented, and its performance is measured in a analysis in a finite element moddeling, and showed itself efficienty. This vibration model for the detector is the best one ever made for spherical detectors, if compared to the literature. Results obtained showed that the atennuation in all the analysed systems are compatible to the Mário Schenberg detector design goals, it means that, the remaining noises are below the expected thermal noise at the temperature of 50 mK.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
TeseFabioBortoli.pdf (9.58 Mbytes)
Data de Publicação
2012-05-21
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.