Título en portugués
Sistemas vibracionais do detector de ondas gravitacionais Mário Schenberg.
Palabras clave en portugués
Detetores
Instrumentação (astronomia)
Método dos elementos finitos.
Ondas gravitacionais
Vibrações
Resumen en portugués
O detector de ondas gravitacionais Mário Schenberg consiste de uma massa ressonante esférica de Cu(94%)Al(6%) com 65cm de diâmetro, pesando aproximadamente 1,15T, com um Q mecânico da ordem de 106 e todos os sistemas que possibilitam o seu funcionamento como detector de ondas gravitacionais. O projeto do detector prevê para este uma sensibilidade da ordem de 10-20 (em deformação). Para isso dependerá da eficiência dos sistemas vibracionais que utiliza. Neste trabalho os casadores mecânicos de impedância, foram simulados com um programa de elementos finitos e otimizados quanto à sua banda e acoplamento vibracional. Foi feita a análise do sistema de isolamento vibracional da nova suspensão, por meio da resposta em frequência do ruído sísmico na superfície da esfera, nos mesmos locais onde estão conectados os transdutores. Foi proposto um projeto novo para atenuar os ruídos provenientes do cabeamento que conduz os sinais de micro-ondas. Foi avaliado o efeito do ruído sísmico introduzido na suspensão e na esfera, também nos locais dos transdutores, utilizando este novo projeto. É apresentado um projeto para a conexão térmica do refrigerador por diluição, que a análise por simulação numérica demonstrou ser eficaz. A modelagem para análise vibracional é a melhor já feita para detectores esféricos, isto se comparada às que foram encontrados na literatura. Os resultados alcançados demonstraram que as atenuação em todos os sistemas analisados são adequadas às metas do projeto do detector Mário Schenberg, ou seja, os ruídos remanescentes estão abaixo do ruído térmico esperado na temperatura de 50mK.
Título en inglés
Vibrational systems of the Mario Schenberg gravitational wave detector.
Palabras clave en inglés
Detectors
Finite element
Gravitational waves
Instrumental (astronomy)
Method.
Vibrations
Resumen en inglés
The Gravitational Wave detector Mario Schenberg consist of a spherical resonant-mass made of CuAl(6%) with 65 cm diameter e weighting 1.15 Ton, with a Mechanical quality factor of about 106 and all the systems that allows it to word as a gravitational wave detector. The detector design was made for it to reach a sensitivity of 10-20 (strain sensitivity). To reach this goal it depends on the efficiency of the it vibrational systems. In this work the transducers mechanical impedance matchers were simulated with a finite element program and optimized in its band and vibrational coupling. A analysis of the vibrational isolation of the new suspension was made by the frequency response of the seismic noise on the sphere surface, on the same places where they will be connected to the transducers. A new design for attenuation of the noise due to microwave cabling was proposed. The seismic noise introduced on the suspension and on the sphere was simulated using this new design. A design for the dilution refrigerator thermal connection is presented, and its performance is measured in a analysis in a finite element moddeling, and showed itself efficienty. This vibration model for the detector is the best one ever made for spherical detectors, if compared to the literature. Results obtained showed that the atennuation in all the analysed systems are compatible to the Mário Schenberg detector design goals, it means that, the remaining noises are below the expected thermal noise at the temperature of 50 mK.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
TeseFabioBortoli.pdf (9.58 Mbytes)
Fecha de Publicación
2012-05-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.