• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.43.1987.tde-28022014-144037
Document
Auteur
Nom complet
Martha Aurelia Aldred
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1987
Directeur
Jury
Watanabe, Shigueo (Président)
Dias Neto, Alipio Luiz
Robilotta, Cecil Chow
Titre en portugais
Estudo "in vivo" da influência de heterogeneidade de tecidos na distribuição de dose em terapias com raios x de alta energia
Mots-clés en portugais
Dosimetria TL
Heterogeneidade de tecidos
Medidas \"in vivo\"
Radioterapia
Resumé en portugais
O estudo dos efeitos da heterogeneidade de tecidos nas doses administradas em radioterapia tem sido alvo de diversos trabalhos. A maioria deles mostra medidas "in vitro" em fantomas homogêneos nos quais são introduzidos materiais que simulam a presença de ossos ou de cavidades de ar. No presente trabalho optou-se por um estudo "in vivo" para o qual utilizou-se como instrumento de medida a dosimetria termoluminescente, bastante apropriada por motivos bem conhecidos. Foram escolhidos oito pacientes com tumor na região pélvica, tratados com raios x do Acelerador Linear de 4 MeV do Instituto de Radioterapia Osvaldo Cruz. A relação entre as doses medidas na entrada e na saída do feixe quando comparada ao valor previsto para fantomas homogêneos, indica a influência da heterogeneidade na distribuição da dose. A análise das medidas efetuadas nos oito pacientes, mostrou que a dose administrada ao centro do tumor pode ser 8% menor do que aquela planejada sem levar-se em conta a referida heterogeneidade.
Titre en anglais
In vivo study of the influence of tissue inhomogeneity on dose distribution in high energy X ray therapy
Mots-clés en anglais
Radiotherapy
Tissue heterogeneity
TL dosimetry
\"In vivo\" measures
Resumé en anglais
Several authors investigated the effect of the heterogeneity of tissue in the dose distribution in a radiation therapy. Practically all of them carried out "in vitro" measurements using a solid body immersed in a water phantom, in order to simulate the inhomogeneity, such as bone, air cavity, etc. In the present work, "in vivo" measurements were performed utilizing thermoluminescent dosimeters, whose appropriateness and convenience are well known. Eight patients at Instituto de Radioterapia Oswaldo Cruz were selected, that were under irradiation treatments in their pelvic region. The ratio between body entry radiation dose and the corresponding exit dose, when compared to the same ratio for a homogeneous phantom, gives the influence of the heterogeneity of the tissue the radiation crosses. The results found in those eight patients have shown that "in vivo" measurements present a ratio about 8% smaller than in homogenous phantom case.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
maldred.pdf (10.19 Mbytes)
Date de Publication
2014-02-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.