Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.43.1987.tde-28022014-144037
Documento
Autor
Nome completo
Martha Aurelia Aldred
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 1987
Orientador
Banca examinadora
Watanabe, Shigueo (Presidente)
Dias Neto, Alipio Luiz
Robilotta, Cecil Chow
Título em português
Estudo "in vivo" da influência de heterogeneidade de tecidos na distribuição de dose em terapias com raios x de alta energia
Palavras-chave em português
Dosimetria TL
Heterogeneidade de tecidos
Medidas \"in vivo\"
Radioterapia
Resumo em português
O estudo dos efeitos da heterogeneidade de tecidos nas doses administradas em radioterapia tem sido alvo de diversos trabalhos. A maioria deles mostra medidas "in vitro" em fantomas homogêneos nos quais são introduzidos materiais que simulam a presença de ossos ou de cavidades de ar. No presente trabalho optou-se por um estudo "in vivo" para o qual utilizou-se como instrumento de medida a dosimetria termoluminescente, bastante apropriada por motivos bem conhecidos. Foram escolhidos oito pacientes com tumor na região pélvica, tratados com raios x do Acelerador Linear de 4 MeV do Instituto de Radioterapia Osvaldo Cruz. A relação entre as doses medidas na entrada e na saída do feixe quando comparada ao valor previsto para fantomas homogêneos, indica a influência da heterogeneidade na distribuição da dose. A análise das medidas efetuadas nos oito pacientes, mostrou que a dose administrada ao centro do tumor pode ser 8% menor do que aquela planejada sem levar-se em conta a referida heterogeneidade.
Título em inglês
In vivo study of the influence of tissue inhomogeneity on dose distribution in high energy X ray therapy
Palavras-chave em inglês
Radiotherapy
Tissue heterogeneity
TL dosimetry
\"In vivo\" measures
Resumo em inglês
Several authors investigated the effect of the heterogeneity of tissue in the dose distribution in a radiation therapy. Practically all of them carried out "in vitro" measurements using a solid body immersed in a water phantom, in order to simulate the inhomogeneity, such as bone, air cavity, etc. In the present work, "in vivo" measurements were performed utilizing thermoluminescent dosimeters, whose appropriateness and convenience are well known. Eight patients at Instituto de Radioterapia Oswaldo Cruz were selected, that were under irradiation treatments in their pelvic region. The ratio between body entry radiation dose and the corresponding exit dose, when compared to the same ratio for a homogeneous phantom, gives the influence of the heterogeneity of the tissue the radiation crosses. The results found in those eight patients have shown that "in vivo" measurements present a ratio about 8% smaller than in homogenous phantom case.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
maldred.pdf (10.19 Mbytes)
Data de Publicação
2014-02-28
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.