• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.43.1999.tde-20022014-152226
Document
Author
Full name
Marco Aurelio Lisboa Leite
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1999
Supervisor
Committee
Dietzsch, Olacio (President)
Fauth, Anderson Campos
Hamburger, Ernst Wolfgang
Shellard, Ronald Cintra
Silva, Ruy Pepe da
Title in Portuguese
Calorímetro de Líquidos Nobres para Radiações de Alta Energia
Keywords in Portuguese
Alta energia
Calorimetria
Líquidos Nobres
Abstract in Portuguese
Este trabalho descreve a construção e testes de um calorímetro eletromagnético de criptônio liquido utilizando uma geometria projetiva na forma de acordeom para os absorvedores eletrodos. Testes do calorímetro com feixes de elétrons de energia entre 20 e 200 GeV, realizados na linha de feixe H4 do acelerador SPS do CERN, apontam para uma resolução em energia de 5.63/(E[GeV] )0.26)% e uma não linearidade integral máxima de +/- 0,3%. O calorímetro é dividido longitudinalmente em 3 seções, sendo a primeira altamente segmentada transversalmente em uma direção, formando um pre-shower integrado ao calorímetro. A posição de incidência da partícula no calorímetro pode ser determinada com uma resolução de 2.16/(E[GeV] )0,19 7.93 / E[GeV])mm no pre-shower e o ângulo de incidência da partícula (utilizando a informação de posição das outras seções) com uma resolução de (32.01/(E[GeV] ) 0.95 44 /E[GeV])mrad. Os sinais do calorímetro permitem a realização de medidas de tempo com uma resolução de 290ps com elétrons de 120 GeV. Também são apresentados e discutidos o efeito da presença de material inativo na resolução em energia, a resposta do calorímetro a múons e os resultados da comparação entre simulações de Monte Carlo com medidas feitas com feixes de partículas. Por fim, é feito um estudo comparativo da resolução em energia obtida com este calorímetro e com um calorímetro de argônio liquido de geometria semelhante.
Title in English
Noble Liquid Calorimeter High-energy Radiation
Keywords in English
Calorimetry
High energy physics
Noble liquids
Abstract in English
This work describes the construction and tests of a liquid krypton electromagnetic calorimeter employing an accordion shaped projective geometry for the absorbers and electrodes. The tests of the calorimeter using electron beams of energy ranging from 20 to 200 GeV and a muon beam of 225 GeV, from the H4 beam line of the CERN SPS, showed an energy resolution of 5,63/(E[GeV] ) 0.26)% and a maximum integral non-linearity of +/- 0.3%. the calorimeter is divided longitudinally in 3 sections, the first one being highly segmented on the transversal direction, operating as a pre-shower integrated on the calorimeter. The position of incidence for a particle in the calorimeter can be determined with a resolution of (2.16/E[GeV] 0.19 7.93 /E[GeV])mm on the pre-shower and the angle of incidence (using the position information from all sections) with a resolution of (32.01/E[GeV] 0.95 44 /E[GeV])mrad. The calorimeter signal allow timing measurements to be performed with a resolution of 290ps for 120 GeV electrons. It is also presented and discussed the energy resolution behavior in the presence of dead material in front of the calorimeter, the calorimeter response to muons and the comparison between the results from data and Monte Carlo calculations. Finally, it is presented a comparative study between the energy resolution of this calorimeter and a liquid argon calorimeter employing a similar accordion shaped geometry.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
39819Leite.pdf (28.69 Mbytes)
Publishing Date
2014-02-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.