• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.43.1990.tde-17062015-151653
Documento
Autor
Nome completo
Vera Lucia Cervini Procida Veissid
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 1990
Orientador
Banca examinadora
Cruz, Manoel Tiago Freitas da (Presidente)
Saxena, Rajendra Narain
Ueta, Nobuko
Título em português
Correlação experimental de ângulo sólido para correlação angular gama-gama
Palavras-chave em português
Correção de ângulo sólido
Correlação angular gama-gama
Eficiência de detetores Ge(Li)
Resumo em português
Foi efetuado o mapeamento da eficiência intrínseca no fotopico de dois detetores Ge(Li) do tipo falso coaxial, com fótons colimados de uma fonte de 152Eu de 1 mCi, em f unção da direção de incidência. Este mapeamento permitiu efetuar experimentalmente a correção de ângulo sólido para experimentos de correlação angular gama-gama. Esta correção não possui hipóteses como: detetor perfeitamente cilíndrico, ou com seu eixo coincidente com aquele do invólucro. A aplicação da informação de eficiência para a correção de dados de correlação angular implicou em um novo método de análise, onde é ajustada a eles uma expressão do tipo: W(?)= ?.[1+ ?_(kpar>0)??Akk .?_(m= -k)^k?C_km .e^(-1m?)]? onde os Ckm são coeficientes complexos. A qualidade do método foi verificada com a análise de correlações angulares presentes nos decaimentos dos isótopos 60Co e 100Rh com misturas multipolares conhecidas. Os resultados obtidos foram satisfatórios, demonstrando a qualidade dos métodos de mapeamento e de análise da função de correlação angular.
Título em inglês
Solid angle experimental correction for gamma-gamma angular correlation
Palavras-chave em inglês
Gamma-gamma angular correlation
Ge (Li) detectors efficiency
Solid angle correction
Resumo em inglês
The scanning of the intrinsic photopeak efficiency for two Ge(Li) detectors, of false coaxial type (wrap around) was performed with collimated photons from a 152Eu source with 1 mCi, as a function of the direction of incidence. This scanning allowed to obtain experimentally the solid angle correction, to be used in gamma-gamma angular correlation experiments. This correction have no hypotheses like: detector perfectly cylindrical, or with its axis coincident with the end cup axis. The efficiency information applied for the correction of angular correlation data involved a new analysis method, where it is fitted to the data an expression Iike this W(?)= ?.[1+ ?_(kpar>0)??Akk .?_(m= -k)^k?C_km .e^(-1m?)]? the Ckm are complex coefficients. The quality of the method was checked with data analysis of angular correlation functions present in the 60Co and 100Rh decays, with known multipole mixtures. The results were satisfactory, demonstrating the quality of both methods, detector mapping and analysis of correlation functions.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Procida_1990.pdf (4.10 Mbytes)
Data de Publicação
2015-06-17
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.