• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.43.1990.tde-17062015-151653
Document
Auteur
Nom complet
Vera Lucia Cervini Procida Veissid
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1990
Directeur
Jury
Cruz, Manoel Tiago Freitas da (Président)
Saxena, Rajendra Narain
Ueta, Nobuko
Titre en portugais
Correlação experimental de ângulo sólido para correlação angular gama-gama
Mots-clés en portugais
Correção de ângulo sólido
Correlação angular gama-gama
Eficiência de detetores Ge(Li)
Resumé en portugais
Foi efetuado o mapeamento da eficiência intrínseca no fotopico de dois detetores Ge(Li) do tipo falso coaxial, com fótons colimados de uma fonte de 152Eu de 1 mCi, em f unção da direção de incidência. Este mapeamento permitiu efetuar experimentalmente a correção de ângulo sólido para experimentos de correlação angular gama-gama. Esta correção não possui hipóteses como: detetor perfeitamente cilíndrico, ou com seu eixo coincidente com aquele do invólucro. A aplicação da informação de eficiência para a correção de dados de correlação angular implicou em um novo método de análise, onde é ajustada a eles uma expressão do tipo: W(?)= ?.[1+ ?_(kpar>0)??Akk .?_(m= -k)^k?C_km .e^(-1m?)]? onde os Ckm são coeficientes complexos. A qualidade do método foi verificada com a análise de correlações angulares presentes nos decaimentos dos isótopos 60Co e 100Rh com misturas multipolares conhecidas. Os resultados obtidos foram satisfatórios, demonstrando a qualidade dos métodos de mapeamento e de análise da função de correlação angular.
Titre en anglais
Solid angle experimental correction for gamma-gamma angular correlation
Mots-clés en anglais
Gamma-gamma angular correlation
Ge (Li) detectors efficiency
Solid angle correction
Resumé en anglais
The scanning of the intrinsic photopeak efficiency for two Ge(Li) detectors, of false coaxial type (wrap around) was performed with collimated photons from a 152Eu source with 1 mCi, as a function of the direction of incidence. This scanning allowed to obtain experimentally the solid angle correction, to be used in gamma-gamma angular correlation experiments. This correction have no hypotheses like: detector perfectly cylindrical, or with its axis coincident with the end cup axis. The efficiency information applied for the correction of angular correlation data involved a new analysis method, where it is fitted to the data an expression Iike this W(?)= ?.[1+ ?_(kpar>0)??Akk .?_(m= -k)^k?C_km .e^(-1m?)]? the Ckm are complex coefficients. The quality of the method was checked with data analysis of angular correlation functions present in the 60Co and 100Rh decays, with known multipole mixtures. The results were satisfactory, demonstrating the quality of both methods, detector mapping and analysis of correlation functions.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Procida_1990.pdf (4.10 Mbytes)
Date de Publication
2015-06-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.