• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.42.2012.tde-09112012-115558
Documento
Autor
Nome completo
Luana de Cássia Umeda
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2012
Orientador
Banca examinadora
Mehnert, Dolores Ursula (Presidente)
Carmona, Rita de Cássia Compagnoli
Mucci, José Luiz Negrão
Título em português
Métodos clássicos e moleculares para avaliação da qualidade virológica de lodo de esgoto e de água de reúso: determinação da eficiência e limites de detecção.
Palavras-chave em português
Adenovírus
Lodo de esgoto
Reúso da água
Rotavírus
Saneamento
Resumo em português
Os vírus entéricos humanos são encontrados no esgoto e em subprodutos dos processos de tratamento. Recentemente vem sendo recomendados como indicadores de qualidade microbiológica em normas da legislação brasileira e também nas de outros países, mas ainda com parâmetros a definir. O objetivo do estudo é a avaliação e a comparação entre métodos clássicos e moleculares aplicados à detecção de vírus entéricos em amostras de água de reúso e de lodo, visando subsidiar a legislação brasileira. Ensaios de semeadura experimental de protótipos de rotavírus e de adenovírus foram realizados nas matrizes ambientais e os vírus detectados por métodos clássicos (cultivo celular e reação de imunoperoxidase) e moleculares (PCR/nested-PCR, RT-PCR e ICC-PCR), determinando-se os limites de detecção de cada método para cada matriz. A pesquisa de rotavírus e adenovírus presentes naturalmente em 25 amostras de água de reúso e em 25 de lodo possibilitou a comparação dos métodos propostos. O ICC-PCR mostrou ser o método mais factível a ser aplicado na área de saneamento.
Título em inglês
Standard and molecular methods for surveillance of human enteric viruses in sludge and reclaimed water: efficiency and detections limits.
Palavras-chave em inglês
Adenovirus
Reclaimed water
Rotavirus
Sanitation
Sludge
Resumo em inglês
Human enteric viruses are common contaminants of raw sewage and subproducts of sewage treatment processes. In recent years, those viruses were recommend as new microbiological indicators in different matrices in Brazilian legislation and others countries, although some questions should be elucidated. At present, the aim was to evaluate and compare the efficiencies of standard and molecular virological methods for detection of human enteric viruses in sludge and reclaimed water samples. Rotavirus and adenovirus were experimentally spiked in the proposed matrices and virus recovery and detection limits established for each method and matrice. Viruses naturally presented in 25 samples of sludge and 25 samples of reclaimed water were assayed by all methods and results evaluated and compared for statistical significance. From all methods evaluated, ICC-PCR showed to be the most suitable for virus surveillance in sludge and reclaimed water.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2013-02-08
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.