• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.42.2012.tde-09112012-115558
Documento
Autor
Nombre completo
Luana de Cássia Umeda
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Mehnert, Dolores Ursula (Presidente)
Carmona, Rita de Cássia Compagnoli
Mucci, José Luiz Negrão
Título en portugués
Métodos clássicos e moleculares para avaliação da qualidade virológica de lodo de esgoto e de água de reúso: determinação da eficiência e limites de detecção.
Palabras clave en portugués
Adenovírus
Lodo de esgoto
Reúso da água
Rotavírus
Saneamento
Resumen en portugués
Os vírus entéricos humanos são encontrados no esgoto e em subprodutos dos processos de tratamento. Recentemente vem sendo recomendados como indicadores de qualidade microbiológica em normas da legislação brasileira e também nas de outros países, mas ainda com parâmetros a definir. O objetivo do estudo é a avaliação e a comparação entre métodos clássicos e moleculares aplicados à detecção de vírus entéricos em amostras de água de reúso e de lodo, visando subsidiar a legislação brasileira. Ensaios de semeadura experimental de protótipos de rotavírus e de adenovírus foram realizados nas matrizes ambientais e os vírus detectados por métodos clássicos (cultivo celular e reação de imunoperoxidase) e moleculares (PCR/nested-PCR, RT-PCR e ICC-PCR), determinando-se os limites de detecção de cada método para cada matriz. A pesquisa de rotavírus e adenovírus presentes naturalmente em 25 amostras de água de reúso e em 25 de lodo possibilitou a comparação dos métodos propostos. O ICC-PCR mostrou ser o método mais factível a ser aplicado na área de saneamento.
Título en inglés
Standard and molecular methods for surveillance of human enteric viruses in sludge and reclaimed water: efficiency and detections limits.
Palabras clave en inglés
Adenovirus
Reclaimed water
Rotavirus
Sanitation
Sludge
Resumen en inglés
Human enteric viruses are common contaminants of raw sewage and subproducts of sewage treatment processes. In recent years, those viruses were recommend as new microbiological indicators in different matrices in Brazilian legislation and others countries, although some questions should be elucidated. At present, the aim was to evaluate and compare the efficiencies of standard and molecular virological methods for detection of human enteric viruses in sludge and reclaimed water samples. Rotavirus and adenovirus were experimentally spiked in the proposed matrices and virus recovery and detection limits established for each method and matrice. Viruses naturally presented in 25 samples of sludge and 25 samples of reclaimed water were assayed by all methods and results evaluated and compared for statistical significance. From all methods evaluated, ICC-PCR showed to be the most suitable for virus surveillance in sludge and reclaimed water.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-02-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.