• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.39.2018.tde-20122017-113940
Document
Auteur
Nom complet
Rafael Yokoyama Fécchio
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Forjaz, Cláudia Lúcia de Moraes (Président)
Basso, Luciano
Chehuen, Marcel da Rocha
D'Avila, Kátia de Angelis Lobo
Titre en portugais
Reprodutibilidade da hipotensão pós-exercício e de seus mecanismos hemodinâmicos e autonômicos
Mots-clés en portugais
Concordância
Confiabilidade
Erro sistemático
Exercício
Modulação autonômica
Pressão arterial
Resumé en portugais
A hipotensão pós-exercício (HPE) se caracteriza pela redução da pressão arterial (PA) após uma sessão de exercício. Diversos estudos têm investigado a HPE e seus mecanismos utilizando as seguintes formas de cálculo: I = PA pós-exercício - PA pré-exercício; II = PA pós-exercício - PA pós-controle; e III = [(PA pós-exercício - PA pré-exercício) - (PA pós-controle - PA pré-controle)]. Embora esses estudos tenham demonstrado a ocorrência da HPE em diferentes populações e sua relevância clínica, pouco se sabe sobre sua reprodutibilidade. Dessa forma, este estudo objetivou verificar a reprodutibilidade (erro sistemático, confiabilidade e concordância) da HPE e de seus mecanismos hemodinâmicos e autonômicos avaliados pelas 3 formas de cálculo expostas. Para tanto, 30 indivíduos realizaram 4 sessões experimentais divididas em 2 blocos (teste e reteste). Cada bloco foi composto por uma sessão de exercício (cicloergômetro, 45min, 50% do VO2pico) e uma controle (repouso sentado), realizadas em ordem aleatória. Antes e após as intervenções, foram medidos: a PA (auscultatória e fotopletismográfica), o débito cardíaco (reinalação de CO2), a frequência cardíaca (FC - eletrocardiograma) e a modulação autonômica cardiovascular (análise espectral das variabilidades da FC e da PA, além da sensibilidade barorreflexa). A presença de erro sistemático foi avaliada pelo test-t pareado, a confiabilidade pelo coeficiente de correlação intraclasse (CCI) e a concordância pelo erro típico (ET). A HPE e seus mecanismos hemodinâmicos e autonômicos avaliados pelas 3 formas de cálculo não apresentaram erro sistemático. A HPE sistólica apresentou confiabilidade alta e a diastólica confiabilidade baixa a moderada, com melhor confiabilidade na forma de cálculo II. Em geral, os mecanismos hemodinâmicos e autonômicos apresentaram confiabilidade moderada a baixa, com maior confiabilidade com a forma de cálculo I. Para finalizar, os parâmetros de concordância variaram entre as 3 formas de cálculo, o que implica que o ET específico de cada variável para cada forma de cálculo deve ser considerado para a estimativa do tamanho amostral necessário em estudos e para o cálculo da mínima diferença detectável na prática clínica quando o objetivo for comparar as respostas pós-exercício obtidas em diferentes condições
Titre en anglais
Reproducibility of post-exercise hypotension and its hemodynamic and autonomic mechanisms
Mots-clés en anglais
Agreement
Autonomic regulation
Blood pressure
Exercise
Reliability
Systematic error
Resumé en anglais
Post-exercise hypotension is characterized by a reduction in blood pressure (BP) after a single session of exercise. Several studies have investigated PEH and its mechanisms and they have employed the following methods of calculation: I = post-exercise BP - pre-exercise BP; II = post-exercise BP - post-control BP; and III = [(post-exercise BP - pre-exercise BP) - (post-control BP - pre-control BP)]. Although these studies have demonstrated the occurrence of PEH in different populations and its clinical relevance, little is known about the reproducibility of PEH. Thus, the current study was designed to determine the reproducibility (systematic error, reliability and agreement) of PEH and its hemodynamic and autonomic mechanisms evaluated by the three methods of calculation exposed. For this purpose, 30 subjects performed 4 experimental sessions divided into two blocks (test and retest). Each block was composed by one exercise (cycle ergometer, 45 min, 50% of VO2peak) and one control (seated rest) session executed in a random order. Before and after the interventions, the following parameters were measured: BP (auscultatory and photoplethysmographic), cardiac output (CO2 rebreathing), heart rate (HR - electrocardiogram) and cardiovascular autonomic modulation (spectral analysis of HR and BP variabilities, as well as spontaneous baroreflex sensitivity). The presence of systematic bias was evaluated by paired t-test, reliability by intraclass correlation coefficient (ICC) and agreement by typical error (TE). PEH and its hemodynamic and autonomic mechanisms evaluated by the three methods of calculation did not present systematic bias. Systolic PEH presented high reliability and diastolic PEH showed low to moderate reliability, with better results for the method II. In general, the hemodynamic and autonomic mechanisms presented low to moderate reliabilities, with better results for the method I. Lastly, agreement parameters varied among the three methods of calculation, which implies that the specific value of TE for each variable and each method of calculation should be used for estimating the sample size required in studies and establishing the minimal detectable change in clinical settings when the goal is to compare post-exercise responses obtained in different conditions
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-01-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.