• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.39.2008.tde-12112009-162424
Documento
Autor
Nombre completo
Rômulo Cássio de Moraes Bertuzzi
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Kiss, Maria Augusta Peduti Dal Molin (Presidente)
Franchini, Emerson
Kokubun, Eduardo
Nakamura, Fabio Yuzo
Pereira, Benedito
Título en portugués
Estimativa dos metabolismos anaeróbios no déficit máximo acumulado de oxigênio
Palabras clave en portugués
Excesso do consumo de oxigênio após o exercício
Metabolismo anaeróbio lático
Reposta cinética off do consumo de oxigênio
Teste anaeróbio de Wingate
Resumen en portugués
O objetivo desse estudo foi averiguar a possibilidade de se estimar os componentes anaeróbios do déficit máximo acumulado de oxigênio (MAOD) utilizando apenas o consumo de oxigênio (VO2). Adicionalmente, foi proposto um método alternativo que não necessita utilizar a extrapolação do VO2 do exercício submáximo para estimar a demanda de O2 para o exercício supramáximo. Para tanto, dez sujeitos fisicamente ativos foram submetidos aos seguintes testes: a) teste progressivo até a exaustão para determinar a carga correspondente ao consumo de oxigênio (WVO2max); b) seis testes de cargas constantes com intensidades abaixo da WVO2max (40-90% WVO2max); c) um teste a 110% da WVO2max; d) teste anaeróbio de Wingate. A fração do metabolismo anaeróbio alático foi estimada pela fase rápida do excesso do VO2 após o exercício (EPOCRÁPIDO), ao passo que a fração do metabolismo anaeróbio lático foi determinada tanto pela diferença entre MAOD e o EPOCRÁPIDO (MAODLA-1) como pelo acúmulo de lactato no sangue (MAODLA-2). O MAODMOD foi calculado pela somatória do EPOCRÁPIDO com MAODLA-2. Os principais resultados foram: a) as estimativas das contribuições do metabolismo anaeróbio lático não eram estatisticamente diferentes (MAODLA-1 = 2,40 ± 0,66 l; MAODLA-2 = 2,20 ± 0,4 l; p > 0,05); b) similarmente, os resultados do MAOD (3,03 ± 0,62 l) MAODMOD (2,84 ± 0,41) não eram significativamente diferentes (p > 0,05); c) foram detectadas correlações positivas entre MAODMOD, EPOCRÁPIDO, MAODLA-2 e os índices do teste de Wingate; d) os valores percentuais do EPOCRÁPIDO e do MAODLA-1 eram 22 ± 9% e 78 ± 9%, respectivamente. Esses resultados sugerem que os componentes anaeróbios do MAOD podem ser estimados satisfatoriamente utilizando somente o VO2 e que o MAOD pode ser determinado mediante MAODmod
Título en inglés
Estimating of anaerobic metabolisms for maximal accumulated oxygen deficit
Palabras clave en inglés
Anaerobic alactic metabolism
Anaerobic lactic metabolism
Excess post-exercise oxygen uptake
Oxygen off-transient response
Wingate anaerobic test
Resumen en inglés
The objective of this study was ascertain the possibility of estimate the anaerobic components of the maximal accumulated oxygen deficit (MAOD) used only oxygen uptake (VO2). In addition, was proposed an alternative method (MAODMOD) to determine the MAOD without using the extrapolation from submaximal VO2 to estimate the O2 demand of supramaximal exercise. Thus, ten subjects physically active performed the following tests: a) a maximal incremental exercise test for the measurement of the power output correspondent to maximal oxygen uptake (WVO2max); b) six submaximal tests with intensities bellow of the WVO2max (40-90% WVO2max); c) a supramaximal test at 110% WVO2max; d) Wingate anaerobic test. The fraction of the anaerobic alactic metabolism was calculated based on the fast component of excess post-exercise oxygen uptake (EPOCRÁPIDO), although the fraction of the anaerobic lactic metabolism was calculated based on both difference between MAOD and EPOCRÁPIDO (MAODLA-1) and changes in net blood lactate accumulation (MAODLA-2). MAODMOD was calculated by the sum of the EPOCRÁPIDO with the MAODLA-2. The main results were: a) non significant difference was found between the anaerobic lactic estimates (MAODLA-1 = 2,40 ± 0,66 l; MAODLA-2 = 2,20 ± 0,4 l; p > 0,05); b) similarly, there was no significant difference (p > 0,05) between MAOD (3,03 ± 0,62 l) and MAODMOD (2,84 ± 0,41); c) positive and significant correlation were detected between MAODMOD, EPOCRÁPIDO, MAODLA-2 and the indices of the Wingate anaerobic test (p < 0,05); d) the mean of the percentage values of the EPOCRÁPIDO and MAODLA-1 were 22 ± 9% e 78 ± 9%, respectively. These data suggest that the anaerobic components of the MAOD can be satisfactorily estimated using only the VO2 and that the MAOD can be determined using the MAODmod
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
TeseRomulo.pdf (3.85 Mbytes)
Fecha de Publicación
2010-03-12
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.