• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2016.tde-22072016-164428
Documento
Autor
Nombre completo
Vitor Mori
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Moriya, Henrique Takachi (Presidente)
Alencar, Adriano Mesquita
Carvalho, Alysson Roncally Silva
Título en portugués
Impedância respiratória de entrada: comparação entre os métodos convencional e de wavetube.
Palabras clave en portugués
Bioengenharia
Impedância
Mecânica respiratória
Modelo de fase constante
Técnica das oscilações forçadas
Resumen en portugués
A impedância respiratória de entrada pode ser obtida pela Técnica das Oscilações Forçadas (FOT) através de dois métodos diferentes: convencional e de wavetube. Nessa dissertação, primeiramente realizamos uma revisão bibliográfica com enfoque nos assuntos de interesse para esse trabalho, como definições e modelagem de impedância, descrições e bases teóricas para a realização dos dois métodos e descrição dos equipamentos utilizados por cada um dos métodos. A partir de dados experimentais da impedância, em camundongos machos do tipo BALB/c normais, obtidos em dois equipamentos diferentes fez-se uma comparação utilizando como base o Modelo de Fase Constante, analisando possíveis divergências e buscando compreender os motivos de eventuais discrepâncias. Um dos equipamentos (flexiVent, SCIREQ, Canadá) emprega o método convencional enquanto o outro equipamento foi desenvolvido pelo grupo do professor Zoltán Hantos, da Universidade de Szeged, Hungria, e se utiliza do método de wavetube. Tal trabalho foi motivado pela ausência de referências bibliográficas que comparam os dois métodos. A análise dos resultados experimentais nos sugere que os parâmetros obtidos para o Modelo de Fase Constante nos dois equipamentos são diferentes e não comparáveis.
Título en inglés
Input respiratory impedance: comparison between conventional and wavetube methods.
Palabras clave en inglés
Biomedical engineering
Constant phase model
Forced oscillations technique
Impedance
Respiratory mechanics
Resumen en inglés
The input respiratory impedance can be obtained by two different methods of performing the Forced Oscillations Technique (FOT): conventional and wavetube method. In this dissertation, first we made a literature review focusing on issues of interest to this work, as definitions and models of impedance, description and theoretical basis for the realization of the two methods and description of the equipments used by each method. Using experimental data of impedance in BALB/c male mice, from two different equipments a comparison was made based on the Constant Phase Model, analyzing possible differences between them and trying to understand the reasons for any discrepancies. The first equipment (flexiVent, SCIREQ, Canada) uses the conventional method while the second one, developed by the research group of Professor Zoltán Hantos of the University of Szeged, Hungary, uses the wavetube method. This work was motivated by the lack of literature references comparing the model parameters obtained by both methods. The analysis of experimental results suggests that the equipments are different and not comparable.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
VitorMoriOrig15.pdf (3.60 Mbytes)
Fecha de Publicación
2016-07-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.