• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2011.tde-31052011-153716
Document
Author
Full name
Renato Seiji Tavares
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Tsuzuki, Marcos de Sales Guerra (President)
Amato, Marcelo Britto Passos
Furuie, Sérgio Shiguemi
Title in Portuguese
Segmentação do pulmão em sequências de imagens de ressonância magnética utilizando  a transformada de Hough.
Keywords in Portuguese
Ressonância magnética
Segmentação do pulmão
Transformada de Hough
Abstract in Portuguese
A segmentação é uma etapa intermediária no registro e reconstrução 3D do pulmão. Geralmente, os métodos de segmentação são interativos e utilizam diferentes estratégias para combinar a expertise dos humanos e a velocidade e precisão dos computadores. A segmentação de imagens RM do pulmão é particularmente difícil devido à grande variação na qualidade da imagem. Dois métodos para a segmentação do contorno do pulmão são apresentados. No primeiro, uma análise individual de cada imagem da série de imagens RM é realizada, e a segmentação ocorre através de técnicas de limiarização e labeling. No segundo método, a respiração é associada a uma função respiração padrão, e através de técnicas de processamento de imagem 2D, detecção de bordas e transformada de Hough, padrões respiratórios são obtidos e, conseqüentemente, a posição dos pontos no tempo são estimados. Seqüências temporais de imagens RM são segmentadas, considerando a coerência no tempo. Desta forma, a silhueta do pulmão pode ser determinada em cada quadro, mesmo em quadros com bordas obscuras. A região do pulmão é segmentada em três etapas, neste método: uma máscara contendo a região do pulmão é criada a partir do resultado do primeiro método de segmentação; a transformada de Hough é aplicada exclusivamente aos pixels da máscara em diversos planos; o contorno do pulmão é extraído do resultado da transformada de Hough utilizando os contornos ativos. O formato da máscara pode ter uma grande variação, e a transformada de Hough modificada pode lidar com essa variação. Os resultados obtidos pelos dois métodos são comparados.
Title in English
Lung segmentation from magnetic resonance image sequences using Hough transform.
Keywords in English
Hough transform
Lung segmentation
Magnetic resonance
Abstract in English
The segmentation of the lung is an intermediary step towards its registry and 3D reconstruction. Usually, segmentation methods are interactive and make use of different strategies to combine the expertise of the human and the computers accuracy and speed. Segmentation of lung magnetic resonance (MR) images is particularly difficult because of the large variation in image quality. Two methods for the lung contour segmentation are presented. In this first method, an individual analysis of each image in the series approach is taken, and the segmentation is made through thresholding and labeling techniques. In the second method, the breathing is associated to a standard respiratory function, and through 2D image processing, edge detection and Hough transform, respiratory patterns are obtained and, consequently, the position of points in time are estimated. Temporal sequences of MR images are segmented by considering the coherence in time. This way, the lung silhouette can be determined in every frame, even on frames with obscure edges. The lung region is segmented in three steps: a mask containing the lung region is created from the results of the first method; the Hough transform is applied exclusively to mask pixels in different planes; and the lung contour is created from the results of the Hough transform through active contours. The shape of the mask can have a large variation, and the modified Hough transform can handle such a shape variation. Results from both methods are compared.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-06-30
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • Sato, A. K., et al. Registration of Temporal Sequences of Coronal and Sagittal MR Images Through Respiratory Patterns [doi:10.1016/j.bspc.2010.08.002]. Biomedical Signal Processing and Control [online], 2011, vol. 6, p. 34-47.
  • Abe, L. I., et al. Diaphragmatic Surface Reconstruction from MR Temporal Sequences of Images. In COBEM 2011 - 21 International Congress of Mechanical Engineering, Natal, 2011. Proceedings of COBEM2011.Rio de Janeiro : ABCM, 2011.
  • Chirinos, J. M. M., et al. Segmentação Temporal do Contorno Pulmonar em Sequências de Imagens de RM por Meio de Superfícies Ativas. In VII Congresso Nacional de Engenharia Mecânica, São Luis, 2012. Anais do VII Congresso Nacional de Engenharia Mecânica.Rio de Janeiro : ABCM, 2012.
  • Stevo, N., et al. Registration of Temporal Sequences of Coronal and Sagittal Images Obtained from Magnetic Resonance. In 20th International Congress of Mechanical Engineering, Gramado, 2009. Proceedings of the 20th International Congress of Mechanical Engineering.Rio de Janeiro : ABCM, 2009.
  • Takimoto, R. Y., et al. Detecting Function Pattern with Interval Hough Transform [doi:10.1109/INDUSCON.2010.5740072]. In 9th IEEE/IAS International Conference on Industry Applications, São Paulo, 2010. Proceedings of the 9th IEEE/IAS International Conference on Industry Applications.São Paulo : IEEE, 2010.
  • Tavares, R. S., et al. Comparison of Two Lung Segmentation Algorithms from MRI Temporal Sequences [doi:10.2316/P.2011.742-030]. In IASTED International Conference Computational Bioscience (CompBio 2011), Cambridge, 2011. Proceedings of the IASTED International Conference Computational Bioscience (CompBio 2011).Alberta : IASTED, 2011.
  • Tavares, R. S., et al. Lung Movement Determination in Temporal Sequences of MR Images Using Hough Transform and Interval Arithmetics [doi:10.3182/20090812-3-DK-2006.00033]. In 7th IFAC Symposium on Modeling and Control in Biomedical Systems (including Biological Systems), Aalborg, 2009. Proceedings of the 7th IFAC Symposium on Modeling and Control in Biomedical Systems (including Biological Systems).Aalborg : IFAC, 2009.
  • Tavares, R. S., et al. Temporal Segmentation of Lung Region from MRI Sequences Using Multiple Active Contours [doi:10.1109/IEMBS.2011.6091969]. In 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, 2011. Proceedings of the 33nd Annual International Conference of the IEEE EMBS.Boston : IEEE, 2011.
  • Tavares, R. S., et al. Temporal Segmentation of Lung Region MR Image Sequences Using Hough Transform [doi:10.1109/IEMBS.2010.5628023]. In 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Buenos Aires, 2010. Proceedings of the 32nd Annual International Conference of the IEEE EMBS.Buenos Aires : IEEE, 2010.
  • Abe, L. I., et al. Determinação Automática do Movimento da Superfície Diafragmática a Partir de Sequências Temporais Sagitais e Coronais de Imagens de RM. In 3.o Encontro Nacional de Engenharia Biomecânica, Foz de Iguaçu, 2011. Anais do 3.o Encontro Nacional de Engenharia Biomecânica.Rio de Janeiro : ABCM, 2011. Resumo.
  • Tavares, R. S., et al. Determination of the Lung Movement in Temporal Sequences of Magnetic Ressonance Images. In Symposium Brazil-Japan in Economy, Science and Technological Innovations, São Paulo, 2008. Proceedings of the Symposium Brazil-Japan in Economy, Science and Technological Innovations. : Brazil Japan Researchers Association, 2008.
  • Tavares, R. S., e Tsuzuki, M. S. G. Segmentação Temporal do Pulmão a Partir de Imagens de Ressonância Magnética Utilizando Transformada de Hough. In 3.o Encontro Nacional de Engenharia Biomecânica, Foz de Iguaçu, 2011. Anais do 3.o Encontro Nacional de Engenharia Biomecânica.Rio de Janeiro : ABCM, 2011. Resumo.
  • Tavares, R. S., e Tsuzuki, M. S. G. Visualização e Análise de Sequências de Imagens Temporais de Ressonância Magnética do Pulmão Utilizando Aritmética Intervalar. In 15o SIICUSP - Simpósio Internacional de Iniciação Científica, São Carlos, 2007. CD-ROM., 2007. Resumo.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.