Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2014.tde-26122014-170653
Documento
Autor
Nombre completo
André Avelãs Machado de Araujo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Tannuri, Eduardo Aoun (Presidente)
Forner Cordero, Arturo
Siqueira, Adriano Almeida Gonçalves
Título en portugués
Desenvolvimento de controle de impedância aplicado a exoesqueleto biomecatrônico atuado por liga de memória de forma.
Palabras clave en portugués
Biomecatrônica
Controle de impedância
Exoesqueleto
Ligas de memória de forma
Órtese
Robótica
Resumen en portugués
O seguinte trabalho visa o estudo, desenvolvimento e teste de um controlador de impedância genérico, que seja adequado para controle de exoesqueletos e outros sistemas robóticos, e que permita a utilização de um atuador de liga de memória de forma (SMA), entre outros tipos de atuador. Um segundo objetivo é avaliar a viabilidade da utilização de atuadores de SMA em aplicações de exoesqueletos para humanos, partindo dos resultados obtidos com o controlador e atuador propostos. Para atingir estas metas, foi projetado e construído um protótipo de exoesqueleto de membro inferior com um grau de liberdade, sendo que um atuador baseado em fios de liga de memória de forma foi utilizado. O algoritmo de controle de impedância foi desenvolvido e testes foram realizados primeiro por meio de simulações e posteriormente em ensaios práticos com o protótipo. Os resultados experimentais confirmaram a expectativa indicada pelos resultados numéricos. Embora o controlador de impedância haja funcionado como se pretendia, o atuador deixou a desejar devido, sobretudo, à sua lentidão de resposta. O texto apresenta uma breve revisão teórica sobre controle de impedância, exoesqueletos biomecatrônicos e ligas de memória de forma. Ademais, detalha o modelo matemático do problema e o aparato experimental projetado para realizar os ensaios que serviram de base para a análise do problema. Após apresentação e discussão dos resultados, é feita uma análise da viabilidade de aplicação destes conceitos a exoesqueletos para uso em humanos, concluindo que ainda há desafios tecnológicos importantes a serem vencidos antes da implementação prática de exoesqueletos com atuadores de SMA; contudo, esta implementação não pode ser descartada. Detalhes construtivos e programas desenvolvidos para simulações e controle do protótipo são apresentados nos apêndices.
Título en inglés
Development of impedance control applied to shape memory alloy actuated biomechatronic exoskeleton.
Palabras clave en inglés
Biomechatronics
Exoskeleton
Impedance control
Orthose
Robotics
Shape memory alloys
Resumen en inglés
This work proposes the study, development and test of a generic impedance controller, which must be adequate to control exoskeletons as well as other robotic systems, and must allow the use of a shape memory alloy (SMA) actuator, among others kinds of actuation. A second objective is to evaluate if it is possible to use SMA actuators in exoskeletons for humans, taking into account the results obtained with the proposed controller and actuator. To achieve such goals, a one degree of freedom, lower limb exoskeleton prototype was designed and built, while an actuator based on SMA wires was used. The impedance control algorithm was developed and tests were made, first by means of simulations and later by tests on the prototype. Experimental data confirmed the expected results obtained by simulations. Although the impedance controller has worked as desired, the actuator did not meet the expectations, especially because of its slow response. The text brings a brief theoretical review about impedance control, biomechatronic exoskeletons and shape memory alloys. In addition, it details the mathematical model of the problem and the experimental apparatus, designed to the execution of tests which would serve as a foundation to the problem analysis. After the results are presented and discussed, the viability of use of the proposed concepts to SMA-actuated-exoskeletons is analyzed, concluding that there are still important technological challenges to be overcome before the practical implementation of exoskeletons with SMA actuators; however, this implementation cannot be discarded. Constructive details of the prototype and the programs developed to simulate and control it are presented in the appendixes.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.