Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2009.tde-21122009-140042
Document
Author
Full name
Andres Choi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Silva, Emílio Carlos Nelli (President)
Buiochi, Flávio
Saenz, Juan Sergio Romero
Title in Portuguese
Desenvolvimento de uma bomba de fluxo piezelétrica de diafragma.
Keywords in Portuguese
Atuadores piezelétricos
Dinâmica dos fluídos
Método dos elementos finitos
Abstract in Portuguese
Bombas de fluxo são dispositivos importantes em áreas como a Bioengenharia, Medicina, Farmácia, entre outras aplicações clássicas de Engenharia. Princípios para o bombeamento de fluidos baseados em atuadores piezelétricos estão sendo estudados no Departamento de Engenharia Mecatrônica e de Sistemas Mecânicos da Escola Politécnica, que permitem a construção de bombas de fluxo de pequena escala, ou seja, bombas de fluxo de pequena potência para deslocamento de pequenos volumes de fluido com baixo consumo de energia. O presente trabalho estuda bombas de fluxo piezelétricas de diafragma do tipo valve-less para geração de vazão. A bomba de fluxo piezelétrica de diafragma utiliza cerâmica piezelétrica como atuador para mover uma membrana (diafragma) para cima e para baixo como um pistão, que causa uma seqüência de aumento e diminuição do volume da câmara da bomba, forçando a entrada e a saída do fluido na bomba. A direção do fluxo é garantida por válvulas que privilegiam o fluxo em apenas um sentido. O objetivo deste trabalho é o estudo da metodologia de desenvolvimento de uma bomba de fluxo piezelétrica de diafragma de baixo custo do tipo valve-less. Para tanto, será utilizado a modelagem por Método dos Elementos Finitos (MEF) para a realização de análises de sensibilidade dos parâmetros geométricos e construtivos da bomba de fluxo. Serão realizadas simulações de escoamento de fluido pelo Método de Volumes Finitos (MVF) para a realização de análises de sensibilidade dos parâmetros geométricos dos elementos difusor/bocal e o levantamento das curvas características da bomba de fluxo. Por fim, protótipos serão construídos e caracterizados para validação dos resultados computacionais. Serão apresentadas a metodologia empregada e a discussão dos resultados obtidos, de forma a analisar o princípio proposto e os fenômenos físicos em questão.
Title in English
A low cost piezoelectric valve-less diaphragm pump.
Keywords in English
Finite element method
Fluid dynamics
Piezoelectric actuator
Abstract in English
Flow pumps act as important devices in areas as Bioengineering, Medicine, Pharmacy, among other areas of Engineering. Principles for pumping fluids based on piezoelectric actuators have been studied in the Department of Mechatronic and Mechanical Engineering of Escola Politécnica da Universidade de São Paulo, that allow the construction of small flow pumps, in other words, pumps for displacement of small fluid volumes with low power consumption. The present work studies valveless piezoelectric diaphragm flow pumps for flow generation. The piezoelectric diaphragm flow pump uses a piezoelectric ceramic as actuator to move a membrane (diaphragm) up and down as a piston. Consequently, there is a sequence of increase and decrease in the chamber volume that will force the fluid in and out of the pump. The direction of the flow is guaranteed by valves that privilege the flow in just one pumping direction. The main objective of this work is the study of a methodology to develop a low cost valve-less piezoelectric diaphragm flow pump. A sensitivity analysis is carried using computational simulation through the Finite Element Method (FEM) to study how construction parameters and assembly affect diaphragm flow pump performance. Using CFD simulations through the Finite Volume Method (FVM), a sensitivity analysis is done around nozzle/diffuser element geometrical parameters and pump characteristic curves are obtained. Finally, computational results are validated by prototype construction and characterization. The text presents methodologies employed and discusses the obtained results, analyzing the principle and the related physical phenomena.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.