Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2012.tde-16072013-120406
Documento
Autor
Nombre completo
Claudia Natalia Lara Herrera
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
González Lima, Raúl (Presidente)
Bevilacqua, Joyce da Silva
Mueller, Jennifer Lynn
Orlande, Helcio Rangel Barreto
Ragazzo, Clodoaldo Grotta
Título en portugués
Um método D-bar para estimar admitividade em 2-D através de tomografia por impedância elétrica.
Palabras clave en portugués
Método de impedância
Tomografia
Resumen en portugués
Propõe-se um novo método D-bar de Tomografia por Impedância Elétrica (TIE) para obter, simultaneamente, a condutividade e a permitividade de um domínio 2-D. O algoritmo direto baseia-se na prova de existência e unicidade do artigo de E. Francini [1]. A caracterização de tecidos biológicos é fortemente facilitada a partir do conhecimento de suas propriedades elétricas. Particularmente, nas aplicações médicas de TIE há grande interesse na permitividade, uma vez que, vários autores tem apresentado critérios para distinguir patologias baseados nesta propriedade, um exemplo constitui a determinação de presença ou ausência de sangue em líquidos acumulados no pulmão. Realizam-se testes com dados simulados numericamente e experimentais com o propósito de verificar e entender as propriedades, capacidades e limitações do algoritmo implementado. No caso dos testes numéricos, é desenvolvido um programa que resolve o problema direto da admitividade, o qual permite calcular conjuntos de dados de voltagem numéricos. São simulados dados aplicando padrões de corrente trigonométricos e por pares. As soluções exponencialmente crescentes do problema inverso são parte essencial do algoritmo e devem ser decompostas nas bases dos padrões de injeção de corrente. A compreensão da natureza destas decomposições para padrões de injeção trigonométricos e por pares, levou ao estabelecimento de especificações no projeto de um sistema de TIE para este algoritmo. Os resultados encorajadores numéricos e experimentais obtidos nas reconstruções de condutividade e permitividade, quanto à resolução espacial e às magnitudes, indicam que o algoritmo é promissor para uso clínico.
Título en inglés
A D-bar method for recovering admittivity in 2-D electrical impedance tomography.
Palabras clave en inglés
Impedance method
Tomographic
Resumen en inglés
This work proposes a new D-bar method of Electrical Impedance Tomography (EIT) for reconstructing the conductivity and permittivity simultaneously in a 2-D domain. The direct algorithm presented is based on the existence and uniqueness proof by E. Francini [1]. Biological tissue characterization is strongly facilitated by the knowledge of its electric properties. In EIT medical applications there is great interest in the permittivity as an additional property for distinguishing pathologies. For instance, the determination of presence or absence of blood in fluid accumulation in the lung. Numerical and experimental data tests are carried out in order to verify and understand the properties, capabilities and limitations of the implemented algorithm. A numerical phantom to solve the forward admittivity problem is developed which allows to simulate voltage data sets. Trigonometric and pairwise injection current patterns are applied. Exponentially growing solutions of the inverse problem are a key part of the algorithm, which have to be expanded in terms of the current patterns. Understanding the nature of these expansions for trigonometric and pairwise injection current patterns leads to a set of specifications in the design of an EIT system for this algorithm. The encouraging numerical and experimental results obtained in conductivity and permittivity reconstructions, regarding the magnitude and spatial resolution, indicate that the algorithm is promising for clinical use.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-07-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.