Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2016.tde-04032016-115750
Document
Author
Full name
William Scaff
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Horikawa, Oswaldo (President)
Andrade, Aron Jose Pazin de
Hirakawa, Andre Riyuiti
Title in Portuguese
Precisão em posicionamento de manipulador não condutor acionado por músculos artificiais pneumáticos.
Keywords in Portuguese
Atuador
Compatível à RM
Manipuladores
Não condutor
Não ferromagnético
Abstract in Portuguese
Com o crescimento populacional e a demanda energética crescente, a sociedade contemporânea têm enfrentado novos desafios para se manter. A aplicação da robótica em diversas áreas está cada vez mais comum, contribuindo para suprir estes novos desafios. Contudo, ainda existem casos em que o uso da robótica convencional é proibitivo, como em ambientes com campos elétricos e/ou magnéticos intensos, encontrado, por exemplo, nos sistemas de distribuição de energia elétrica e em máquinas de ressonância magnética. Isto porque os componentes condutores e ferromagnéticos utilizados podem oferecer perigos, causando queimaduras, curtos-circuitos e até lançamento de componentes. Em vista destas dificuldades, este trabalho propõe a construção de um manipulador robótico capaz de atuar nestas condições de campos elétricos e magnéticos elevados. Na construção de tal dispositivo, entretanto, é necessário o estudo da estrutura mecânica, dos atuadores, dos sensores e do controlador. No caso da estrutura mecânica e dos sensores, existem alternativas não condutoras disponíveis. O controlador geralmente é um microcomputador ou um dispositivo eletrônico, portanto condutor. Uma alternativa é manter o controlador distante e isolado do ambiente de risco. Mas para que esta hipótese seja testada, é necessário um atuador não condutor e não ferromagnético. Por isso, este trabalho propõe a construção de um atuador livre de materiais ferromagnéticos e condutores baseado no músculo artificial pneumático de McKibben. Músculos artificiais pneumáticos são disponíveis comercialmente, entretanto possuem materiais metálicos. Além disso, o controle preciso destes atuadores é dificultado pela sua alta não linearidade. Para verificar a viabilidade da aplicação de músculos artificiais em um manipulador não condutor, foram realizados testes com protótipos de músculos artificiais construídos com materiais compatíveis. O projeto e o dimensionamento do músculo artificial é abordado. Finalmente, é realizado o controle PID do músculo para avaliar sua controlabilidade e viabilidade de aplicação para tarefas de precisão em posicionamento.
Title in English
Positioning precision of a non conducting manipulator powered by pneumatic artificial muscles.
Keywords in English
Actuator
Manipulator
MRI compatible
Non conductive
Non ferromagnetic
Abstract in English
With the population growth and the evergrowing energy dependency, the contemporary society have been facing new challenges to maintain yourself. The use of robotics in various fields is each time more common, contributing to surpass these new challenges. However, there are still cases where applying conventional robotics is prohibitive, such as in high electric and magnetic field environments, found, for example, in electric energy distribution systems and in magnetic resonance imaging machines. That's because conductive and ferromagnetic components can cause serious problems, like burns, short-cuts and even be throwed at high velocities. Knowing these difficulties, this work proposes the construction of a robotic manipulator capable of acting in these high electric and magnetic field environments. To build such manipulator, however, it's necessary to study the mechanic structure, the actuators, the sensors and the controller. In the case of the mechanic structure and sensors, there exists non-conductive and non-magnetic alternatives available. The controller is, in general, a microcomputer or an electric device, therefore, conductive. One alternative is to keep the controller far away from the risk environment. But to test this hypothesis, it's necessary to have a non-conductive and non-ferromagnetic actuator. Because of that, this work proposes the construction of an actuator free of conductive and magnetic materials, based on the McKibben pneumatic artificial muscle. Pneumatic artificial muscles are available commercially, but they have metallic components. Besides, the accurate control of these actuators is difficult for their high non-linearities. To verify the viability of applying artificial muscles on a non-conductive manipulator, tests were conducted with artificial muscle prototypes built with compatible materials. The design and dimensioning of the artificial muscle are covered. Finally, the PID controller is implemented to evaluate the muscle's controllability and its viability for tasks that need position accuracy.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-03-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.