• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2017.tde-27092017-082902
Document
Auteur
Nom complet
Antonio Luiz Zambelli Loyola Gonzaga Mendonça
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Hernandez Neto, Alberto (Président)
Saidel, Marco Antonio
Vittorino, Fulvio
Titre en portugais
Avaliação energética e econômica de um ciclo de refrigeração por absorção aplicado a hotéis.
Mots-clés en portugais
Absorção
Cogeração de energia elétrica
Hotéis
Refrigeração
Resumé en portugais
A demanda por encontrar soluções que possam proporcionar um melhor aproveitamento de energia em edificações hoteleiras é crescente, tornando-se essencial na realidade vivida neste setor nos últimos tempos ao redor do mundo. O aumento da eficiência energética em hotéis por meio da aplicação de sistemas de cogeração representa um notório ganho de competitividade, tornando-se um fator decisivo para hóspedes e empresários, além de contribuir para a sustentabilidade do empreendimento. A fim de aumentar a eficiência energética em edificações hoteleiras, este trabalho apresenta a otimização de sistemas de cogeração com ciclo de absorção aplicado a hotéis. Levou-se em consideração a realidade do setor em metrópoles brasileiras, baseando-se no fato de que estas cidades recebem um número crescente de turistas por ano, tanto para eventos culturais quanto para negócios, e precisam buscar soluções para reduzir o consumo de energia elétrica. Além disso, nos últimos anos, o Brasil vem enfrentando um aumento expressivo do custo da energia elétrica. A matriz energética brasileira continua contando com uma parcela principal de eletricidade gerada por usinas hidrelétricas, porém é cada vez maior o uso de usinas termelétricas nesta matriz, para compensar de modo geral a redução no volume de chuvas e o aumento da demanda do país por eletricidade. Sendo assim, é necessário buscar fontes alternativas para a produção de energia, assim como incentivar o uso da cogeração por meio de sistemas com maior eficiência na geração e conversão energética. Hotéis possuem forte potencial para aplicação de sistemas de cogeração justamente por conter equipamentos com diversas necessidades energéticas (tanto térmica quanto elétrica). A partir da modelagem de todos os componentes que fazem parte do sistema de cogeração, tais como a câmara de combustão, turbina, caldeira a vapor e resfriador por absorção, fez-se um estudo das variáveis que podem proporcionar uma maior influência na condição de máxima eficiência do sistema como um todo. Vale ressaltar que fatores climáticos, sazonais, flutuações na disponibilidade e no custo das fontes energéticas (sejam estas renováveis ou não) fazem parte da realidade local, e precisam ser levadas em consideração neste estudo. Para o escopo deste trabalho, será abordado um ciclo de refrigeração por absorção que utiliza solução de amônia e água (NH3 + H2O). Para suprir a demanda do ciclo por absorção por energia térmica no gerador, levou-se em consideração a queima do gás liquefeito do petróleo como insumo deste sistema. Serão apresentados fatores que podem contribuir para a redução do consumo elétrico da edificação, reduzindo-se assim a dependência da eletricidade e possibilitando o uso de combustíveis alternativos. Além disso, as interações entre os diversos componentes que compõem o sistema de cogeração, aliada aos variados consumos de energia em um empreendimento hoteleiro (tais como a climatização de ar nos ambientes, uso de água quente em chuveiros, eletricidade), serão avaliados de modo a otimizar a eficiência energética da edificação como um todo.
Titre en anglais
Technical and economic feasibility of a cogeneration system applied to hotels in Brazil.
Mots-clés en anglais
Absorption
Cogeneration
Hotel
Optimization
Refrigeration
Resumé en anglais
A demand for finding solutions that can provide better energy use in hotel buildings is increasing, becoming essential in the reality experienced in this sector in recent times around the world. An increase in energy efficiency of hotels through the application of cogeneration systems is a marked gain in competitiveness, becoming a decisive factor for guests and hotels' stakeholders, as well as a contribute to the sustainability of the enterprise. In order to increase energy efficiency in hotel buildings, this paper aims to present the optimization of cogeneration systems using absorption refrigeration cycle applied to hotels. It took into account the sector's reality in Brazilian cities, based on the fact that these cities receive an increasing number of tourists every year, both for cultural events and for business, and need to find solutions to reduce their electrical consumption. Moreover, in recent years, Brazil has been experiencing a significant increase in the cost of electricity. The Brazilian energy matrix is still counting on a major portion of electricity generated by hydroelectric power plants, but the use of thermal power plants is increasing in this matrix, in order to offset the reduction in rainfall and the increasing demand of the country for electricity. It is therefore necessary to seek alternative sources for energy production as well as encouraging the use of cogeneration systems through more efficient generation and energy conversion. Hotels have strong potential for application of cogeneration systems precisely because it has several energy appliances' needs (both thermal and electrical). From the modeling of all components forming part of a cogeneration system such as the combustion chamber, turbine, steam boiler and absorption chiller, a study has been made using the variables that can provide a greater influence on the maximum condition efficiency of the system as a whole. It is noteworthy that climatic, seasonal factors, fluctuations in availability and cost of energy sources (whether renewable or not) are part of the local reality, and must be taken into consideration in this study. For the scope of this paper, an absorption refrigeration cycle that uses ammonia and water (NH3 + H2O) has been studied. The burning of liquefied petroleum gas inside the combustion chamber as an energy of the system was considered to meet the absorption refrigeration cycle demand for thermal energy inside the generator. Factors that may help to reduce the electrical consumption of the building will be presented, thus reducing the dependence of electricity and allowing the use of alternative fuels. In addition, the interactions between the various components that make up the cogeneration system, coupled with the varying energy consumption in a hotel building (such as HVAC, use of hot water in showers, electricity) will be assessed in order to optimize the energy efficiency of the whole building.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-09-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.