• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2017.tde-18012017-084005
Documento
Autor
Nombre completo
Alan Junji Yamaguchi
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Baliño, Jorge Luis (Presidente)
Paiva, José Luis de
Rosa, Eugênio Spanó
Título en portugués
Estudo experimental de intermitência severa em um sistema água-ar.
Palabras clave en portugués
Dinâmica dos fluidos
Escoamento multifásico
Física experimental
Intermitência severa
Sistema pipeline-riser
Resumen en portugués
O trabalho tem como objetivo realizar um estudo experimental na bancada do Laboratório Multipropósito de Escoamento Multifásico com o intuito de estudar o fenômeno de intermitência severa em um sistema pipeline-riser com os fluidos água e ar. A intermitência severa pode ocorrer em sistemas pipeline-riser onde o pipeline é descendente seguido de um riser vertical, além de ser necessário a presença de baixas vazões de fluidos. Esse fenômeno é caracterizado por ser cíclico em que há acúmulo de líquido na base do riser e por acabar causando perdas na produção de petróleo e gás devido a grandes flutuações de pressão e vazão que podem durar horas a depender do comprimento do sistema. Os picos de pressão e vazão também podem causar o desligamento do sistema de separação na plataforma. O estudo se dividiu em várias etapas onde inicialmente foram definidos os procedimentos experimentais a serem utilizados. A calibração de placas de orifício foi necessária para o controle de vazão mássica de gás. Os resultados experimentais foram divididos em casos estáveis e instáveis onde a instabilidade é caracterizada pela presença de ciclos de pressão que podem ser observados em históricos de pressão na base do riser. Mapas de estabilidade foram criados e a região instável obtida experimentalmente foi comparada com a curva de estabilidade obtida pelo uso da teoria de estabilidade linear. Os históricos de pressão na base do riser para os casos instáveis obtidos foram comparados com dois modelos numéricos. A variação da pressão no separador foi usada para verificar a mitigação da intermitência severa e/ou da condição instável obtida no sistema para alguns casos instáveis.
Título en inglés
Experimental study of severe slugging in an air-water system.
Palabras clave en inglés
Air-water multiphase flow
Pipeline-riser system
Severe slugging
Resumen en inglés
The objective of this work is to do an experimental study of the severe slugging phenomenon in the pipeline-riser system of the Multipurpose Multiphase Flow Laboratory by using the fluids air and water. Severe slugging may occur for low flow rates in pipeline-riser systems where a downward pipeline is followed by a vertical riser. In this phenomenon there is liquid accumulation at the bottom of the riser resulting in production losses due to the great fluctuations of pressure and flow rate during its cycles which may last for hours depending on the length of the system. The high pressure values can also cause shutdown of the platform separation system. The first stage of this study was to define the experimental procedure to be adopted. It was necessary to perform a calibration of the orifice plates in order to have a precise control of the gas mass flow rate. The experimental results were divided in stable and unstable cases. The instability is defined by the presence of pressure oscillations at the bottom of the riser. Stability maps were created to compare the stabiliy curve obtained by the stability linear theory with the experimental results. The experimental pressure oscillations were compared with two numerical models. The pressure variation at the separator was studied to verify the mitigation effects during unstable and/or severe slugging conditions.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-01-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.