Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2008.tde-11092008-134613
Document
Auteur
Nom complet
Fernanda Tambelli Teixeira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Morita, Dione Mari (Président)
Isaac, Ricardo de Lima
Lage Filho, Frederico de Almeida
Titre en portugais
Avaliação do desenvolvimento da microbiota e da remoção de COT em filtros biologicamente ativos.
Mots-clés en portugais
Biorregeneração
Carvão ativado
Cometabolismo
Tratamento de água
Resumé en portugais
Este trabalho visa avaliar o desenvolvimento microbiano e a capacidade de degradação de carbono orgânico total (COT) em quatro colunas adsorvedoras pósfiltração, em escala de bancada, em três ensaios em batelada: o primeiro de longa duração (84 dias) com afluente de água filtrada clorada com baixa concentração de COT (1,4 mg/L); o segundo de longa duração (84 dias) com afluente de solução de glicose e água filtrada clorada com concentração de COT de 6,0 mg/L e o terceiro de curta duração (21 dias) e com o mesmo afluente utilizado no segundo teste. Foi utilizado carvão ativado granular (CAG) de mesmas características nas colunas adsorvedoras, exceto as faixas de diâmetros dos grânulos, que variaram de 0,5 a 0,71 mm (coluna 1A), de 0,84 a 1,0 mm (coluna 1B) e de 1,0 a 1,19 mm (coluna 1C) nas três colunas que tinham o diâmetro interno de 1,2 cm. A coluna 2, com diâmetro interno de 2,1 cm, recebeu CAG com grânulos na mesma faixa de diâmetros da coluna 1B (0,84 a 1,0 mm). As eficiências de remoção de COT no primeiro ensaio foram bem menores (46 a 74%) do que aquelas dos ensaios 2 (94 a 97%) e 3 (96 a 97%). Estes últimos apresentaram grande desenvolvimento da microbiota e elevadas eficiências de remoção de COT, devido ao co-metabolismo e biorregeneração nas colunas pela introdução da glicose. Nas três colunas de mesmo diâmetro, foi observado que quanto menor a faixa de diâmetros dos grânulos de CAG, maior foi o desenvolvimento da microbiota (expresso em contagens de bactérias heterotróficas); e nas colunas com mesma faixa de diâmetros de CAG e com diferentes diâmetros de coluna (1B e 2), o desenvolvimento da microbiota foi muito semelhante nos ensaios de longa duração. Com relação às eficiências de remoção de COT, não houve diferença significativa entre as quatro colunas nos ensaios de longa e curta duração com adição de glicose; no ensaio de longa duração sem adição de glicose as colunas 1A e 2 apresentaram melhores resultados em relação às demais e não há uma explicação clara para tal fato.
Titre en anglais
Evaluation of microbial growth and total organic carbon removal in biologically active filters.
Mots-clés en anglais
Biologic filter
Granular activated carbon
Water treatment
Resumé en anglais
The major purpose of this experimental work was to evaluate the microbial development and the capabilities of degradation of Total Organic Carbon (TOC) of four post-filtration adsorption columns operated as batch reactors in three bench scale tests. The firs batch column testing was conducted by means of one long duration runs (84 days each) and the columns were fed with filtered, chlorinated water with low COT concentration (1.4 mg/L). The second batch column testing was conducted by means of one long duration runs (84 days each) and the columns were fed with a glucose and filtered chlorinated water solution (resulting TOC = 6.0 mg/L). The third batch column testing was conducted by means of one short duration runs (21 days each) and the columns were fed with the same solution of the second batch column testing. The same type of Granular Activated Carbon (GAC) was employed in all columns, except for the average granule diameter ranges. They were 0.5 to 0.71 mm (column 1A), 0.84 to 1.0 mm (column 1B), and 1.0 to 1.19 mm (column 1C), for the 12 mm diameter columns. The 21 mm diameter column 2 had CAG granules with the same size range of column 1B (0.84 to 1.0 mm). The TOC removal efficiencies in the first batch column testing were lower (46 to 74%) than 2 (94 to 97%) and 3 (96 to 97%) batch column testing. The lasts batch column testing led to high microbial growth and high TOC removal efficiencies due to cometabolism and bioregenation in the columns fed with a glucose. Regarding the three columns with the same diameter, it was observed that the lower the GAC granule size range, the higher the microbial growth rate (expressed as heterotrophic plate count); the columns with the same GAC size range but different column diameters (columns 1B and 2) the microbial growth rates were very similar with respect to the long period runs. With respect to the TOC removal efficiencies, there were no significant differences between the four columns in the long duration test runs and the short duration runs with glucose addition; in the long duration run without glucose addition, columns 1A and 2 were much more efficient at removing TOC than the other column; there is no clear explanation for it.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Dissertacao_Fernanda.pdf (457.73 Kbytes)
Date de Publication
2008-09-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.