Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Mierzwa, José Carlos (Presidente)
Hespanhol, Ivanildo
Mancuso, Pedro Caetano Sanches
Título en portugués
Diretrizes para implantação de sistemas de reúso de água em condomínios residenciais baseadas no método APPCC - análise de perigos e pontos críticos de controle: estudo de caso Residencial Valville I.
Palabras clave en portugués
Análise de perigos e pontos críticos de controle
Condomínios fechados
Reúso da água
Saneamento ambiental
Resumen en portugués
A água é um recurso cada vez mais escasso, seja pelo crescimento populacional, com o aumento da demanda, seja pela redução da oferta, especialmente pela poluição dos mananciais. Uma das alternativas para enfrentar este problema é o reúso de água, importante instrumento de gestão dos recursos hídricos e detentor de tecnologias já consagradas para a sua adequada utilização. O presente trabalho visa estabelecer um protocolo para se utilizar a prática de reúso de água não potável em condomínios residenciais fechados, estilo de moradia em ascensão, localizado normalmente em áreas periféricas urbanas, de difícil acesso ao abastecimento público de água e esgotamento sanitário e com restrições para o lançamento dos esgotos, mesmo tratados, em corpos d'água. Devido a legislação para regulamentação do reúso ainda ser limitada e a incerteza quanto aos riscos à saúde pública inerentes à esta prática, faz-se necessária a adoção do Princípio da Precaução. Com base neste princípio, pode-se adotar a prática do reúso de água contanto que procedimentos e tecnologias adequadas sejam aplicadas. Um gerenciamento de riscos baseado em medidas preventivas como o APPCC (Análise de Perigos e Pontos Críticos de Controle) é uma boa opção para avaliar os programas de reúso de água. Através de uma revisão bibliográfica, da aplicação da metodologia APPCC e do acompanhamento de um estudo de caso no Residencial Valville I, localizado na cidade de Santana do Parnaíba/SP, um conjunto de diretrizes foi elaborado para a adoção da prática de reúso de água não potável em condomínios residenciais. Nesta proposta de diretrizes foram levantados os perigos e os pontos críticos de controle de um sistema de reúso de água em condomínios, as ações emergenciais, sugestões de parâmetros de qualidade da água de reuso e também as formas de conscientização e envolvimento da comunidade. Isto por sua vez contribui para o melhor entendimento da necessidade de regulamentação mais detalhada dos programas de reúso de água exigidos em normas estabelecidas em alguns municípios.
Título en inglés
Guidelines for water reuse system in residential condominiums based on HACCP method: Valville I case study.
Palabras clave en inglés
Condominium
Gated communities
HACCP
Risk management
Water reuse
Resumen en inglés
Water is about to become a scarce resource, due to the population growth that increases the demand or even because of the offer reduction, especially due to water springs´ pollution. One of the alternatives to face this problem is the Water Reuse technique, an important instrument to water management and owner of high technologies to its properly utilization. The aim of this paper is to establish a protocol for using the Non-potable Water Reuse practice in residential condominiums, an upcoming stile of living, usually located at big cities surroundings, where the public potable water supply and the sewage transport are inaccessible. Besides that, there are restrictions to discharge these treated effluents into water courses. Considering the limitation of Brazilian water reuse legislation, and the uncertainties about the public health´s risks concerning the reuse practice, it is necessary to adopt the Precautionary Principle, in which the option of reuse can be employed if the adequate practices and technologies are applied to this purpose. A risk management based on preventive measures like the HACCP (Hazard Analysis and Critical Control Point) consists in one of the best options for the evaluation of water reuse practice. By bibliography review, HACCP´s method application and data collection of a real case study on Valville I - a residential condominium in Santana do Parnaíba/SP, a proposal of guidelines was elaborated to adopt the non-potable water reuse practice inside the residential condominiums. These guidelines considered the hazards and critical control points in a water reuse system in a condominium, the emergency procedures, suggestions of quality parameters for the reuse water and also some ways of teaching and involving the community. This is a contribution for a better understanding of a more detailed regulation for water reuse programs that are enforced by law in some cities.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2008-09-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.