• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.3.2016.tde-03052016-154733
Document
Author
Full name
Daniel Vieira Minegatti de Oliveira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Piveli, Roque Passos (President)
Contrera, Ronan Cleber
Ferreira Filho, Sidney Seckler
Jordão, Eduardo Pacheco
Volschan Junior, Isaac
Title in Portuguese
Avaliação da remoção de nitrogênio via nitrificação e desnitrificação simultânea em um reator biológico com leito móvel (IFAS).
Keywords in Portuguese
Baixa concentração de oxigênio
Desnitrificação
IFAS
Nirogênio (Remoção)
Nitrificação
Respirometria
Tratamento de esgotos sanitários
Abstract in Portuguese
O fenômeno conhecido como Nitrificação e Desnitrificação Simultânea (SND) significa que em um mesmo reator ocorre simultaneamente a nitrificação e a desnitrificação, sob condições de operações idênticas, podendo ser justificada principalmente pela teoria de microambiente no floco ou biofilme. Assim, em um único reator, sob condições controladas de oxigênio dissolvido (OD) e elevados tempos de residênciacelular épossível que ocorra a nitrificação e a criação de zonas anóxicas no interior dos flocos ou biofilme para a ocorrência da desnitrificação. Neste sentido, a tecnologia MBBR/IFAStem como característicaelevado tempo de residência celular do biofilme formado nos meios suporte presentes no reator. Deste modo, neste estudo avaliou-se a remoção de nitrogênio via SND em um sistema IFAS quando submetido a diferentes concentrações de OD e Tempo de DetençãoHidraulica de 5,5 e 11 horas, tratando efluente sanitário e efluente sintético. Os resultados experimentais demonstraram que pode ser possível desenvolver efetiva SND com concentrações de OD média de 1,0 mg.L-1 e 1,5 mg.L-1. Sendo que, foram obtidas eficiência média de remoção de NTde cerca de 68% e concentrações médias efluente de N-NH4 de aproximadamente 5,0 mg L-1, de N-NO3 inferiores a 4,5 mg L-1 e de N-NO2 em torno de 0,1 mg L-1, e com eficiência média de remoção DQO solúvel acima de 90%, quando empregado efluente sintético. Ademais, por meio da avaliação da emissão de Óxido Nitroso (N2O), foi possível comprovar que a desnitrificação ocorreu de forma efetiva.
Title in English
Evaluation of nitrogen removal through simultaneous nitrification and denitrification in Integrated Fixed-film Activated Sludge (IFAS).
Keywords in English
IFAS
Low oxygen concentration
Respirometry
Simultaneous Nitrification and Denitrification (SND)
Abstract in English
The phenomenon known as Simultaneous Nitrification and Denitrification (SND) means that in the same reactor simultaneously occurring nitrification and denitrification under identical operations conditions, and can be mainly explained by the microenvironment theory inside the floc or biofilm. Therefore, in a single reactor under controlled conditions of dissolved oxygen (DO) and high Solids Retention Time (SRT) it is possible that the nitrification happens and the creation of anoxic zones within the flocsor biofilm to the occurrence of the denitrification. In this sense, the MBBR/IFAS technology is characterized by high SRT of the biofilm formed on the carriers present in the reactor. Thereby,this work evaluated the nitrogen removal through SND in a IFAS system when submitted to different DOconcentrations and Hydraulic Retention Time of 5.5 hours and 11.0 hours, treating domestic and synthetic effluents. The experimental results showed that it may be possible to develop effective SND withaverage concentrations of DO of 1.0 mg L-1 and 1.5 mg L-1. It was obtained a TN average removal efficiency about 68%, and an average effluent concentration of NH4-N of approximately 5.0 mg L-1, of NO3-N less than 4.5 mg L-1 and ofNO2-N around 0.1 mg L-1, and an average CODsoluble removal efficiency above 90%, employing synthetic effluent. Furthermore, by evaluating the Nitrous Oxide(N2O) emission, it was possible to prove that the denitrification occurred effectively.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-06-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.