Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2016.tde-17062016-144914
Document
Auteur
Nom complet
Daniel Kina Murakami
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Massad, Faiçal (Président)
Abramento, Mauricio
Aoki, Nelson
Titre en portugais
Novo procedimento para a realização de análise capwap no ensaio de carregamento dinâmico em estacas pré-moldadas.
Mots-clés en portugais
Análise CAPWAP
Ensaio de carregamento dinâmico
Estacas
Match quality de recalques
Prova de carga estática
Resumé en portugais
Desde a década de 1980 diversos autores apresentaram correlações entre provas de carga estática e ensaios de carregamento dinâmico em estacas. Para uma boa correlação é fundamental que os testes sejam bem executados e que atinjam a ruptura segundo algum critério, como o de Davisson, por exemplo, além de levar em conta o intervalo de tempo entre a execução da prova de carga estática e do ensaio dinâmico, face ao efeito "set up". Após a realização do ensaio dinâmico realiza-se a análise CAPWAP que permite a determinação da distribuição do atrito lateral em profundidade, a carga de ponta e outros parâmetros dos solos tais como quakes e damping. A análise CAPWAP é realizada por tentativas através do procedimento "signal matching", isto é, o melhor ajuste entre os sinais de força medido pelos sensores e o calculado. É relativamente fácil mostrar que a mesma solução pode ser obtida através de dados de entrada diferentes. Isso significa que apesar de apresentarem cargas mobilizadas próximas o formato da curva da simulação de prova de carga estática, obtida pelo CAPWAP, assim como a distribuição do atrito lateral, podem ser diferentes, mesmo que as análises apresentem "match quality" (MQWU) satisfatórios. Uma forma de corrigir o formato da curva simulada do CAPWAP, assim como a distribuição do atrito lateral, é através da comparação com provas de carga estática (PCE). A sobreposição das duas curvas, a simulada e a "real", permite a determinação do quake do fuste através do trecho inicial da curva carga-recalque da prova de carga estática, que por sua vez permite uma melhor definição da distribuição do atrito lateral e da reação de ponta. Neste contexto surge o conceito de "match quality de recalques" (MQR). Quando a PCE não está disponível, propõe-se efetuar um carregamento estático utilizando o peso próprio do martelo do bate-estaca (CEPM). Mostra-se, através de dois casos de obra, em que estavam disponíveis ensaios de carregamento dinâmico e PCEs, que esse procedimento permite obter uma melhor solução do ponto de vista físico, isto é consistente com as características do subsolo e com a curva carga-recalque da PCE, e não apenas matemático, através da avaliação do "match quality" (MQWU).
Titre en anglais
New prodedure to perform CAPWAP analysis on dinamic load test in precast concrete piles.
Mots-clés en anglais
CAPWAP analysis
Dynamic load test
Match quality fo settlements
Static load test
Resumé en anglais
Since the 1980s a lot of authors showed correlations between static load tests and dynamic load tests on piles. For a good correlation it is necessary a good execution of the load test, also it is necessary to choose a capacity value from the results of the static load test, for example, the Davisson Offset limit load. The time of execution between the static load test and the dynamic load test should be considered because of the set up effect. Dynamic data may be further analyzed by CAPWAP Method to evaluate the soil resistance distribution, the toe resistance, quake and damping values. It is a signal matching method. Its results are based on the "best possible match" between computed pile top variable such as the pile top force and its measured equivalent. It is easy to demonstrate almost the same pile capacity on CAPWAP using different soil parameters. It means that even the pile capacity is almost the same, the shape of the pile top load-displacement of the CAPWAP Method and the shaft friction distribution can be different, although all results confirm good match quality. One way to correct the shape of the top loaddisplacement of the CAPWAP Method, as well as the shaft friction distribution, is by comparisson to a static load test. Overlaying both curves, the static load test and the CAPWAP Method, it is possible to determine the shaft quake value on the initial loads on the top load-displacement curve, allowing this way a improvement of the shaft resistance distribution and the toe resistance. In this context arises the concept of "match quality of settlements". When the static load test is not avaliabe, this thesis proposes a static load test using the hammer's weight of the pile driving machine. It is shown by two case studies that were available static load tests and dynamic load tests, this procedure allows a better solution on physics aspects, this is consistent with the subsoil conditions and the load-settlement curve of the static load test, not only a mathematical solution based on match quality.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
AnexoD.pdf (1.87 Mbytes)
AnexoE.pdf (860.56 Kbytes)
Date de Publication
2016-06-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.