• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2018.tde-21092018-135055
Document
Auteur
Nom complet
Lucas Coscia Romagnoli
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2018
Directeur
Jury
Silva, Valdir Pignatta e (Président)
Caldas, Rodrigo Barreto
Munaiar Neto, Jorge
Titre en portugais
Análise de vigas mistas de aço e concreto semicontí­nuas em situação de incêndio.
Mots-clés en portugais
Análise termestrutural
Estruturas de aço
Estruturas de concreto
Estruturas metálicas
Estruturas mistas
Incêndio
Vigas
Resumé en portugais
Na Dissertação de Mestrado foi realizado um estudo sobre o comportamento de vigas mistas de aço e concreto biapoiadas sob iteração completa, compostas por perfis classificados como compactos em situação de incêndio. Apesar de ditas biapoiadas, a ideia principal da Dissertação é considerar, na análise em situação de incêndio, a reserva de capacidade existente nas extremidades dessas vigas, usualmente desprezada no dimensionamento à temperatura ambiente, provinda da continuidade da armadura longitudinal negativa presente na laje de concreto, sendo possível dispensar o revestimento contra fogo nesses elementos. Serão abordados, de início, os métodos de dimensionamento ao Estado-Limite Último de vigas mistas à temperatura ambiente, a fim de explicar o comportamento estrutural desse tipo de elemento, dando base para a posterior análise térmica. A análise térmica foi realizada, em uma primeira etapa, por métodos simplificados segundo normas vigentes e tomando hipóteses simplificadoras em que se desprezam esforços indiretos provocados pela dilatação térmica e gradiente térmico, sendo possível aplicar os conceitos no dia a dia de projeto. Numa segunda etapa foi realizada análise termestrutural com modelos numéricos para estudar o comportamento e colapso da viga, sendo os resultados suficientes para validar os valores de TRF encontrados por análise simplificada seguindo métodos normativos. Como conclusão, o ganho de capacidade estrutural da viga, proporcionado pela adoção da ligação mista no apoio, foi suficiente para situações de TRRFs entre 15 min e 21 min, no caso de perfis mais leves, com geometria própria para serem utilizados como vigas de piso de edifícios. Análises mostraram que não é possível justificar a ausência de revestimento contra incêndio para TRRFs de 30 min ou superiores. Tempos inferiores podem ser adotados de acordo com o denominado método do tempo equivalente, limitado a 15 min e são mais usuais para edificações de pequeno porte.
Titre en anglais
Composite steel and concrete semicontinuous beams analysis under fire.
Mots-clés en anglais
Composite steel and concrete structures
Fire
Semicontinuous beams
Steel structures
Thermal structure analysis
Resumé en anglais
A study will be carried out on the behavior of simply supported, full interaction composite steel and concrete beams composed by compact profiles in fire situation. Despite being designed as simply supported, the main idea is to consider, in the fire situation analysis, the moment resistance capacity reserve on the beam supports, usually neglected during room temperature design, due to the upper longitudinal reinforcement present in the concrete slab, being possible to dispense fireproof coating in these elements. First, room temperature design procedures of composite beams will be approached in order to explain the structural behavior of this type of elements, providing a basis for subsequent thermal analysis. The thermal analysis will be carried out, in a first stage, by simplified methods according to design procedures and adopting simplifying hypotheses in which indirect stresses caused by thermal expansion and thermal gradient are neglected, being possible to apply those concepts in structural design offices. In a second step, thermal stress analyses were performed with aid of numerical models to study the structural behavior and collapse time of the beam. The results were sufficient to validate the fire resistance time values found by the simplified analysis following design methods. As a conclusion, the structural capacity increase of the beam, provided by the adoption of the composite connection at the support in case of lighter steel profiles usually chosen to be used as buildings floor beams, was sufficient for situations of standard fire resistance requirements between 15 min and 21 min. Analyzes have shown that it is not possible to justify the absence of fire resistant coating for standard fire resistance requirements of 30 min or higher. Lower times can be adopted according to the so-called equivalent time method, limited to 15 min, which are more common for small buildings.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-09-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.