• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2012.tde-09022013-135226
Document
Auteur
Nom complet
Gabriela Bandeira de Melo Lins de Albuquerque
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Silva, Valdir Pignatta e (Président)
França, Ricardo Leopoldo e Silva
Silva Filho, Luiz Carlos Pinto da
Titre en portugais
Dimensionamento de vigas de concreto armado em situação de incêndio.
Mots-clés en portugais
Análise térmica
Concreto armado
Dimensionamento
Incêndio
Método gráfico
Vigas
Resumé en portugais
As vigas de concreto armado perdem capacidade resistente quando em situação de incêndio. A ferramenta mais prática para o dimensionamento dessas peças é o método tabular, apresentado na ABNT NBR 15200:2012, em que a partir do tempo requerido de resistência ao fogo (TRRF) se encontram a largura mínima da seção transversal e a menor distância admissível entre o centro geométrico da armadura e a face aquecida. Contudo, apesar de simples, ele limita os cálculos a poucos valores tabelados, não permitindo ao engenheiro buscar soluções diferentes. Por isso, nesta Dissertação, desenvolveu-se um método alternativo, com o auxílio do programa de computador sueco Super Tempcalc. A priori, definiu-se o campo de temperaturas de vigas sob lajes sujeitas ao incêndio-padrão ISO 834 (1999), em função do tempo. Em seguida, considerando-se a redução das resistências do concreto e do aço, calculou-se o momento fletor resistente para os diferentes casos estudados. Foram analisadas térmica e estruturalmente vigas com diversas larguras, alturas, cobrimentos, diâmetros e disposições de armaduras. Os momentos resistentes em situação de incêndio derivados do programa foram comparados a valores provindos de métodos simplificados, propostos pelas normas brasileira e europeia (Eurocode 2 parte 1-2, 2004) e, ainda, a um método mais avançado. Após a validação dos dados, criaram-se gráficos que associam o parâmetro µ, relação entre o momento fletor solicitante em situação de incêndio e o momento fletor resistente à temperatura ambiente, ao tempo de resistência ao fogo (TRF), para cada situação de interesse. Esses gráficos, que envolvem tanto armaduras positivas quanto negativas, também permitem levar em conta a redistribuição de momentos, o que conduzirá à otimização na solução encontrada. Nos exemplos de aplicação realizados, os resultados obtidos a partir do método gráfico se mostraram, em geral, mais econômicos, quando comparados aos do método tabular.
Titre en anglais
Reinforced concrete beams fire design.
Mots-clés en anglais
Beams
Design
Fire
Graphic method
Reinforced concrete
Thermal analysis
Resumé en anglais
Reinforced concrete beams lose their load capacity when subjected to fire. The most practical tool for their design is the tabular method, presented in ABNT NBR 15200:2012, in which, from the time required for fire resistance (TRRF), the minimum width of the transversal section and the smallest admissible distance between the centroid of the rebar and the heated face can be found. Yet, albeit simple, it limits the calculation to a few fixed values, not allowing the engineer to seek different solutions. Hence, an alternative method was developed in this Dissertation, using the Swedish Super Tempcalc software. Firstly, the temperature field of beams subjected to ISO 834 (1999) standard fire situation was defined, as a function of time. Next, considering the reduction in concrete and steel strength, the resistance bending moment was calculated for the different cases studied. Beams with different widths, heights, covers, diameters and reinforcing bars dispositions were thermally and structurally analyzed. The resistance moments in fire situation obtained from the software were compared to values deriving from simplified methods, proposed by Brazilian and European (Eurocode 2 part 1-2, 2004) standards, besides a more advanced method. After data validation, graphs were created, associating the parameter µ, ratio between the applied bending moment in fire and the resistance bending moment at ambient temperature, to time for fire resistance (TRF), for each situation of interest. These graphs, involving both positive and negative reinforcement, also allow consideration of the redistribution of moments, which will lead to the optimization of the solution found. In the examples analyzed, the results deriving from the graphic method were generally more economic compared to the tabular method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-03-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.