• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2012.tde-09022013-135226
Document
Author
Full name
Gabriela Bandeira de Melo Lins de Albuquerque
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Silva, Valdir Pignatta e (President)
França, Ricardo Leopoldo e Silva
Silva Filho, Luiz Carlos Pinto da
Title in Portuguese
Dimensionamento de vigas de concreto armado em situação de incêndio.
Keywords in Portuguese
Análise térmica
Concreto armado
Dimensionamento
Incêndio
Método gráfico
Vigas
Abstract in Portuguese
As vigas de concreto armado perdem capacidade resistente quando em situação de incêndio. A ferramenta mais prática para o dimensionamento dessas peças é o método tabular, apresentado na ABNT NBR 15200:2012, em que a partir do tempo requerido de resistência ao fogo (TRRF) se encontram a largura mínima da seção transversal e a menor distância admissível entre o centro geométrico da armadura e a face aquecida. Contudo, apesar de simples, ele limita os cálculos a poucos valores tabelados, não permitindo ao engenheiro buscar soluções diferentes. Por isso, nesta Dissertação, desenvolveu-se um método alternativo, com o auxílio do programa de computador sueco Super Tempcalc. A priori, definiu-se o campo de temperaturas de vigas sob lajes sujeitas ao incêndio-padrão ISO 834 (1999), em função do tempo. Em seguida, considerando-se a redução das resistências do concreto e do aço, calculou-se o momento fletor resistente para os diferentes casos estudados. Foram analisadas térmica e estruturalmente vigas com diversas larguras, alturas, cobrimentos, diâmetros e disposições de armaduras. Os momentos resistentes em situação de incêndio derivados do programa foram comparados a valores provindos de métodos simplificados, propostos pelas normas brasileira e europeia (Eurocode 2 parte 1-2, 2004) e, ainda, a um método mais avançado. Após a validação dos dados, criaram-se gráficos que associam o parâmetro µ, relação entre o momento fletor solicitante em situação de incêndio e o momento fletor resistente à temperatura ambiente, ao tempo de resistência ao fogo (TRF), para cada situação de interesse. Esses gráficos, que envolvem tanto armaduras positivas quanto negativas, também permitem levar em conta a redistribuição de momentos, o que conduzirá à otimização na solução encontrada. Nos exemplos de aplicação realizados, os resultados obtidos a partir do método gráfico se mostraram, em geral, mais econômicos, quando comparados aos do método tabular.
Title in English
Reinforced concrete beams fire design.
Keywords in English
Beams
Design
Fire
Graphic method
Reinforced concrete
Thermal analysis
Abstract in English
Reinforced concrete beams lose their load capacity when subjected to fire. The most practical tool for their design is the tabular method, presented in ABNT NBR 15200:2012, in which, from the time required for fire resistance (TRRF), the minimum width of the transversal section and the smallest admissible distance between the centroid of the rebar and the heated face can be found. Yet, albeit simple, it limits the calculation to a few fixed values, not allowing the engineer to seek different solutions. Hence, an alternative method was developed in this Dissertation, using the Swedish Super Tempcalc software. Firstly, the temperature field of beams subjected to ISO 834 (1999) standard fire situation was defined, as a function of time. Next, considering the reduction in concrete and steel strength, the resistance bending moment was calculated for the different cases studied. Beams with different widths, heights, covers, diameters and reinforcing bars dispositions were thermally and structurally analyzed. The resistance moments in fire situation obtained from the software were compared to values deriving from simplified methods, proposed by Brazilian and European (Eurocode 2 part 1-2, 2004) standards, besides a more advanced method. After data validation, graphs were created, associating the parameter µ, ratio between the applied bending moment in fire and the resistance bending moment at ambient temperature, to time for fire resistance (TRF), for each situation of interest. These graphs, involving both positive and negative reinforcement, also allow consideration of the redistribution of moments, which will lead to the optimization of the solution found. In the examples analyzed, the results deriving from the graphic method were generally more economic compared to the tabular method.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-03-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.