• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2011.tde-31052011-154602
Document
Auteur
Nom complet
Thiago Costa Monteiro
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Komatsu, Wilson (Président)
Chabu, Ivan Eduardo
Marafão, Fernando Pinhabel
Titre en portugais
Proposta de modelo e método para determinação dos parâmetros de transformadores operando em saturação.
Mots-clés en portugais
Conversor conectado à rede CA
Ensaio de transformadores
Modelo de transformador
Saturação de transformador
Transformador
Resumé en portugais
Uma série de equipamentos de eletrônica de potência é ligada à rede de corrente alternada através de transformadores, que exercem as funções de isolamento galvânico, elevação/abaixamento de tensão, etc. Estes transformadores podem sofrer saturação em condições transitórias (inrush) ou quando o conversor ligado a ele impõe valor médio não nulo de tensão. O problema é normalmente sanado nas malhas de controle do conversor, no entanto o ajuste destas malhas em ambiente de simulação computacional requer um modelo que represente adequadamente a característica de saturação do núcleo ferromagnético. Este trabalho apresenta um modelo de simulação computacional adequado para transformadores operando em saturação intensa, visando aplicações em projetos de equipamentos de eletrônica de potência com transformador monofásico alimentado por inversor. Além disso, é demonstrado um método experimental de obtenção da característica de saturação do núcleo, sem necessidade das suas características construtivas. Resultados de simulação obtidos são comparados com resultados experimentais para validação do modelo e método.
Titre en anglais
A proposal of saturated transformer model and its parameter determining method.
Mots-clés en anglais
AC network connected converter
Transformer
Transformer model
Transformer saturation
Transformer tests
Resumé en anglais
Several power electronics based equipments are connected to the alternating current network through transformers, which perform galvanic insulation, voltage increasing/lowering, etc. These transformers may experience saturation under transitory conditions (inrush), or when its converter imposes non-zero average voltage. Such problem is commonly treated in the converter's control loops, but the tuning of these loops in a computer simulation environment requires a transformer model that represents adequately the ferromagnetic core saturation effect. The current work proposes a computer simulation model that adequately describes the operation of the transformer at deep saturation, suitable for design of power electronics applications with single phase transformers connected to power inverter. Additionally, an experimental method for determining its core saturation characteristic is demonstrated. This method does not require previous knowledge of the core's constructive parameters. Simulation and experimental results are presented to confirm the validity of the model and the method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-06-29
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.