Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2014.tde-28082015-102143
Document
Auteur
Nom complet
César Bernardini De Franco
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Nabeta, Silvio Ikuyo (Président)
Silva, Viviane Cristine
Teixeira, Julio Carlos
Titre en portugais
Caracterização de geradores hidrelétricos por ensaio de rejeição de carga.
Mots-clés en portugais
Caracterização de geradores
Ensaio de rejeição de carga
Resumé en portugais
Atualmente, os procedimentos normalizados para determinar os parâmetros transitórios e subtransitórios dos geradores hidrelétricos impõem dificuldades de execução. Assim, em muitos casos, esses ensaios não são realizados e, consequentemente, os respectivos geradores hidrelétricos ficam carentes de uma comprovação em campo de suas características transitórias e subtransitórias. Para preencher essa lacuna, o presente trabalho apresenta uma metodologia para execução do ensaio por rejeição de carga como forma de viabilizar a caracterização de grandes e médios geradores hidrelétricos dentro de determinadas condições e faixa de aplicação.
Titre en anglais
Characterization of hydro generators through load rejection test.
Mots-clés en anglais
Characterization of generators parameters
Load rejection test
Resumé en anglais
Currently, the standards procedures to determine the hydro generators transient and subtransient parameters impose several execution difficulties. Therefore, in several cases those tests cannot be conducted and consequently the respective hydro generators miss a field measurement of its transient and subtransient characteristics. In order to fill this gap, the present work presents a method to execute the load rejection test for determination of medium and large hydro generator parameters.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-09-01
 