• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2016.tde-14072016-144257
Documento
Autor
Nombre completo
Luiz Gustavo Ribeiro
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Pellini, Eduardo Lorenzetti (Presidente)
Chemin Netto, Ulisses
Santos, Milana Lima dos
Título en portugués
Lógica fuzzy aplicados ao registro de alarmes e eventos em subestações no padrão IEC 61850.
Palabras clave en portugués
Alarmes
Controladores programáveis
Eventos.
IEC 61850
Lógica fuzzy
Subestações elétricas
Resumen en portugués
A aplicação de técnicas de Inteligência artificial em sistemas elétricos de potência permite a resolução de problemas onde soluções tradicionais não mostram bons resultados. Por exemplo, após a ocorrência de uma falta, um sistema automatizado toma todas as medidas necessárias para proteger o sistema e assumir um estado seguro de operação. Nessa ocasião, cabe aos operadores verificar todas as mensagens e dados disponíveis, selecionando aquelas relevantes, para então chegar a uma conclusão sobre o evento ocorrido. Apenas após esse diagnóstico, com base em seu conhecimento, o operador pode ordenar o restabelecimento do sistema ou sua manobra para outro estado. Esse processo é lento e passível de falhas, pois as informações são usualmente conflitantes e confusas, devido à avalanche de eventos, alarmes e alertas decorrentes. Diante desta dificuldade, é interessante dispor de uma ferramenta automática de diagnóstico e apoio na tomada de decisão que torne essa tarefa mais ágil e com menores riscos. Este trabalho aborda a integração e a interoperabilidade de equipamentos de uma subestação elétrica em conformidade com a norma IEC 61850, e a utilização de sistemas inteligentes com lógica Fuzzy executados em um controlador programável moderno. O sistema proposto faz uso de recursos de comunicação da IEC 61850, com mensagens prioritárias padrão GOOSE incluindo valores analógicos de corrente de falta, além de mensagens no padrão TCP/IP MMS. Essas informações, alarmes e eventos, são processadas de forma automática por um motor Fuzzy que permite aproximar a decisão computacional à decisão humana, incluindo zonas de incerteza e lógica ponderada, permitindo respostas mais abstratas do que algo puramente binário. O sistema proposto foi submetido a um grande número de eventos com um simulador em tempo real, com equipamentos reais, tais como IEDs e um controlador programável de alto desempenho. Além disso o sistema usou um esquema de comunicação inovador para o módulo do processador de dados em tempo real (RTDP), inteiramente baseado nos protocolos da IEC 61850.
Título en inglés
Fuzzy logic applied to registration of alarms and events in substations in standard IEC 61850.
Palabras clave en inglés
Alarms
Events
Fuzzy logic
IEC 61850
Programmable controllers
Substations
Resumen en inglés
The application of artificial intelligence techniques in electric power systems allows solving problems where traditional solutions do not show good results. For example, in electric power systems, after the occurence of a fault, an automated system takes all necessary measures to protect the system and assume a safe state of operation. On this occasion, it is for operators to review all messages and data available, selecting those relevant to then come to a conclusion about the event that occurred. Only after this diagnosis, based on his knowledge the operator may order the restoration of the system or their operation to another state. This process is therefore slow and subject to failure, because the information is usually conflicting and confusing because of the avalanche of events, alarms and warnings arising. Faced with this difficulty, it is interesting to have an automatic diagnostic tool and support in decision making that makes this task quicker and with less risk. This paper addresses the integration and interoperability of an electrical substation equipment in accordance with IEC 61850, and the use of intelligent systems Fuzzy logic running on a modern programmable controller. The proposed system makes use of the IEC 61850 communication resources with priority GOOSE messages including standard analog values of fault current, as well as messages on standard TCP / IP MMS. This information, alarms and events, are processed automatically by a fuzzy engine that allows the computational approach to human decision making, including areas of uncertainty and weighted logic, allowing more abstract answers than purely binary. The proposed system has undergone a large number of events with a simulator in real time with actual equipment such as a programmable controller IEDs and high performance. In addition the system used an innovative communication scheme for the module's real-time data processor ( RTDP ), based entirely on the IEC 61850 standard protocols such as MMS and GOOSE messages.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-07-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.