"Proteção de plantas termoelétricas industriais operando em co-geração"
Mots-clés en portugais
Cogeração de energia elétrica
Energia térmica
Proteção de sistemas elétricos
Usinas termoelétricas
Resumé en portugais
O trabalho tem por objetivo fazer uma ampla análise das proteções utilizadas no desacoplamento entre a planta termoelétrica industrial operando em co-geração e um grande sistema elétrico. São também analisados os vários tipos de plantas termoelétricas e suas formas operacionais, com relação a planta industrial e a rede da concessionária. Para estes casos foram consideradas as proteções específicas para cada tipo de planta em função das possíveis perturbações a que estas estiverem envolvidas. São apresentadas as principais proteções utilizadas nestes casos, o principio operacional destes relés, e ainda as tecnologias disponíveis para estes componentes. O modelo dinâmico das cargas é analisado com maior precisão, especificamente para o caso das plantas estudadas. Sendo que esse parâmetro tem sido avaliado de forma superficial nos grandes estudos de estabilidade, que nem sempre consideram o desempenho dinâmico das cargas no seu barramento de utilização. Também são analisados os aspectos práticos para determinar a localização das proteções na rede interna, em função da topologia existente e do nível de tensão em que opera a autogeração, caracterizando o comportamento esperado para cada proteção escolhida. Algumas conclusões são tiradas para o modelo de proteção empregada no desacoplamento da autogeração, para as plantas com processos contínuos, enfocando principalmente os problemas de colapso de tensão durante as perturbações, antes e depois da proteção atuar. Também apresentamos um caso típico, por meio de uma simulação dinâmica, onde foram consideradas as principais perturbações provenientes da rede externa e com o sistema isolado, definindo as proteções específicas para este caso simulado.
Titre en anglais
Sem título em inglês.
Mots-clés en anglais
Sem palavras chaves em inglês.
Resumé en anglais
This paper's aim is a broad analysis of the protection elements used for the disconnection of an industrial thermoelectric plant, operating in cogeneration mode, from an important electric public service system. The different types of thermoelectric plant are analysed, considering their relations with the industrial plant and the public network. The usual protections have been considered for each type of plant as a function of the disturbances to which they could be subjected. The main protection elements used in these cases, their operational principles, and the available technologies have been discussed. The dynamic model of the loads has been analysed with greater precision than usual for the plants under consideration. This aspect has been treated superficially in the present stability studies, which not always account for the dynamic performance of loads at their connection bars. The practical considerations that determine the location of protection elements in the plant internal net are analysed as a function of the circuit topology and generation voltage level, showing the behaviour to be expected for each chosen protection. Some conclusions have been drawn for the protection model used for self-generation disconnection in industrial plants with continuous processes, with special regard for the voltage collapse problems during the disturbances, before and after protection operation. A typical case is also presented, by means of dynamicsimulation, considering the main disturbances introduced by the external network and also for the system when isolated, establishing the specific protection to be used in the case under study
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-09-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.