• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2013.tde-10072014-170858
Documento
Autor
Nombre completo
Tarcisio Misael de Lima
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Zanetta Júnior, Luiz Cera (Presidente)
Bartoli, Julio Roberto
Tatizawa, Hédio
Título en portugués
Análise de metodologias para localização de defeitos em cabos isolados de alta tensão do tipo oil filled (OF).
Palabras clave en portugués
Cabo com papel impregnado
Congelamento
Localização de falhas
Traçador perfluorcarbono
Vazamento de óleo
Resumen en portugués
Duas metodologias que podem ser utilizadas na localização de defeitos em cabos isolados de alta tensão do tipo Oil Filled (OF) foram analisadas. As metodologias descritas têm como princípio a localização de vazamentos de óleo, ou seja, todo defeito seguido de vazamento de óleo poderá ser localizado a partir das mesmas. A primeira metodologia é baseada no congelamento dos cabos OF, com a linha desenergizada, a fim de localizar vazamentos de óleo de cabos OF a partir de 300 litros por mês. A segunda metodologia é baseada na utilização de traços de gás perfluorcarbono Perfluorocarbon Tracer (PFT), através de um sistema montado com equipamentos que permitem realizar a localização de vazamentos de óleo de cabos OF a partir de 100 litros por mês, sem a necessidade de desligamento da linha subterrânea. Esta dissertação propõe algumas melhorias na metodologia do congelamento e apresenta as primeiras experiências de utilização do PFT no Brasil para localização de vazamentos de óleo.
Título en inglés
Analysis of methodologies for fault location in high voltage insulated cables oil filled (OF) type.
Palabras clave en inglés
Freeze
Leak location
Oil leakage
Paper impregnated cable
Perfluorocarbon tracer
Resumen en inglés
Two methods that can be used to locate faults in Oil Filled (OF) cables were analyzed. The methods described have the principle of oil leak location. All defects followed by oil leakage can be located using the same. The first method is based in OF cables freezing, with the line outage, in order to locate oil leaks from 300 liters per month and above. The second method is based on the use of tracer gas - Perfluorocarbon Tracer (PFT) and devices that allow to perform the location of oil leaks from 100 liters per month, without the need of underground line outage. This paper proposes some improvements for the freezing method and presents the first experiments in Brazil using PFT to locate oil leakage.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-07-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.