Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2008.tde-09022009-181024
Documento
Autor
Nombre completo
Marcos Rogério Cândido
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Zanetta Júnior, Luiz Cera (Presidente)
Baccalá, Luiz Antonio
Coury, Denis Vinícius
Moreira, Fernando Augusto
Pereira, Carlos Eduardo de Morais
Título en portugués
Aplicação da transformada Wavelet na análise da qualidade de energia em fornos elétricos a arco.
Palabras clave en portugués
Análise de ondaletas-wavelets (análise de séries temporais)
Energia (qualidade)
Forno elétrico
Resumen en portugués
Neste trabalho, desenvolveu-se um novo método para a detecção e classificação dos distúrbios que afetam a qualidade de energia elétrica em sistemas elétricos industriais na presença de fornos elétricos a arco. Durante o processo de fusão dos fornos elétricos a arco, ocorrem diversos eventos que afetam o sistema elétrico ao qual estão inseridos, tendo como características: forma de onda do sinal de corrente altamente desequilibradas e com grande distorção devido aos harmônicos, efeitos de cintilação; bem como afundamento e elevação nos sinais de tensão. O método ora proposto foi aplicado a sinais reais, permitindo a detecção e classificação dos distúrbios múltiplos na forma de onda do sinal de tensão, proveniente da operação dos fornos elétricos a arco. Para tal, foi usada como base do algoritmo, uma técnica baseada na Transformada Wavelet, aplicada aos sinais não-estacionários de uma instalação industrial com três fornos elétricos a arco.
Título en inglés
Application of wavelet transform for power quality analysis in electric arc furnace.
Palabras clave en inglés
Electric arc furnace
Multiple disturbances
Power quality
Wavelet
Resumen en inglés
A new method for the detection and classification of the disturbances that affect the electric power quality in industrial electric systems with electric arc furnaces was developed in this work. During the fusion process of the electric arc furnaces, may occur several events that affect the electric system to which it is inserted may occur, having as characteristic: waveform of the signal of current highly unbalanced and with great distortion due to the harmonic, scintillation effects; as well as sag and swell in the voltage signals.The method proposed was applied to real signals, allowing the detection and classification of the multiple disturbances in the waveform of the voltage signal originating from the operation of the electric arc furnace. For this purpose, a technique based on Wavelet Transform will be used and applied to the not-stationary signals of an industrial installation with three electric arc furnaces.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-08-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.