• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2020.tde-05022020-101955
Document
Author
Full name
Marcelo Meneghetti Peres
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2019
Supervisor
Committee
Manassero Junior, Giovanni (President)
Rocco, Alexandre
Santos, Ricardo Caneloi dos
Title in Portuguese
Análise do desempenho da função de distância em linhas de transmissão que utilizam o unified power flow controller.
Keywords in Portuguese
Controlador unificado de fluxo de potência
Proteção de sistemas elétricos
Sistemas elétricos de potência
Transmissão de energia elétrica por corrente alternada
Abstract in Portuguese
Este trabalho apresenta a análise do comportamento da função de proteção de distância em sistemas de transmissão de energia elétrica que fazem uso de controladores unificados de fluxo de potência (unified power flow controllers. A análise proposta baseia-se em medições de tensões e correntes fornecidas por transformadores de instrumentação, posicionados nas barras onde esse equipamento é instalado, a um dispositivo eletrônico inteligente. O estudo foi elaborado em rotina computacional no software MATLABR e foi submetido a testes por meio de simulações de um sistema de transmissão no ambiente Simulink R. Os resultados obtidos permitem analisar o impacto desse equipamento na proteção assim como a melhor escolha para o posicionamento dos transformadores de instrumentação.
Title in English
Distance function performane analysis on transmission lines using the unified power flow controller.
Keywords in English
Fexible AC transmission systems
Power system protection
Power systems
Unified power flow controller
Abstract in English
This work presents the analysis behavior of the distance protection function in power transmission systems that use unified power flow controllers. The proposed analysis is based on voltage and current measurements provided by instrument transformers, positioned on the buses where this equipment is installed, to an intelligent electronic device. The study was elaborated in a computational routine in the MATLABR software suite and was tested via simulations of a transmission system in the Simulink R environment. The results reveal the impact of this equipment on the protection function and provide information about the best choice for the positioning of the instrument transformers.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2020-02-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.