Titre en portugais
Interferência de harmônicas em equipamentos de medição de energia elétrica.
Mots-clés en portugais
Energia elétrica (qualidade)
Equipamentos de medidas elétricas
Resumé en portugais
Este trabalho aborda a conformidade dos medidores de energia em sistemas não senoidais, na busca do aumento de qualidade no faturamento de energia elétrica. Para tanto, enfoca a medição mais justa e um melhor relacionamento entre concessionária e consumidor. As análises foram realizadas nos laboratórios da Eletropaulo, do Instituto de Eletrotécnica e Energia da Universidade de São Paulo, e no Laboratório do Centro de Estudos em Regulação e Qualidade de Energia (Enerq), USP. Trata-se de um estudo que faz parte de um projeto maior de Pesquisa e Desenvolvimento da Agência Nacional de Energia Elétrica (ANEEL). Seu objetivo foi investigar se a distorção de tensão e corrente nos medidores de faturamento de energia elétrica provoca desvios na energia medida. Pretendeu-se ainda avaliar se as harmônicas inseridas nos medidores eletromecânicos possuem maior ou menor desvio na energia medida, em comparação aos medidores eletrônicos. A metodologia utilizada incluiu levantamento de estudos de pesquisa e desenvolvimento, além de ensaios de laboratório com amostras de equipamentos de dois fabricantes nacionais. Como parâmetros para os ensaios, levantaram-se curvas, por meio de medições de cargas reais. Os resultados das medições obtidas em situações reais foram comparados com aquelas levantadas nos laboratórios. Os resultados dos ensaios laboratoriais foram analisados e comparados com os limites estabelecidos nas normas vigentes, dentre as quais, destacam-se: o Regulamento Técnico Metrológico do INMETRO e os Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional PRODIST. O presente estudo concluiu que os instrumentos ensaiados em conforme normas, quando parametrizados para não considerar a potência de distorção no cálculo de reativo, atendem os parâmetros de exatidão. Esses dados são válidos tanto para as funções de VArh quanto para Wh.
Titre en anglais
Harmonic interference in equipment for measurement of eletrical energy.
Mots-clés en anglais
Harmonics
Metering equipment
Power quality
Resumé en anglais
This work addresses the reliability of energy meters in nonsinusoidal systems, looking for the increase of quality in the electric energy billing. To that purpose, it focuses on a fairer metering and a better relationship between the concessionaire and consumer. The tests were carried through in the laboratories of Eletropaulo, of the Electro-Technology and Energy Institute in the University of São Paulo, and in the Laboratory of the Center of Studies in Power Quality Regulation (Enerq), USP. This study is part of a bigger project in Research and Development of the Electric Energy National Agency (Aneel). Its objective was to investigate whether the distortion of voltage and current in the electric energy billing meters had deviations in the metered energy. It was also intended to evaluate whether the inserted harmonics in the electromechanical meters have greater or minor deviation in the metered energy, in comparison to the electronic meters. The methodology used included a survey of studies, research and development of the electric sector, besides laboratory tests with two national equipment samples. As parameters for the tests, wave were formulated by means of real load metering. The results of the metering obtained in real situations were compared with those collected in the laboratories. The results of the laboratory tests were analyzed and compared with the limits established in the norms in force, amongst which one highlights: the Technical Metrological Regulation from Inmetro and the Electric Power Distribution Procedures in the National Electric System Prodist. The present study concluded the instruments analyzed under normalized conditions, when parameterized to not consider the distortion power in the calculation of reactive, meet the 60Hz frequency, within the accuracy parameters. These data are valid both for the VArh functions and the Wh.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-09-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.