• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2007.tde-27062007-180347
Document
Author
Full name
Alexandre Murakami
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Gutierrez, Marco Antonio (President)
Costa, Eduardo Tavares
Moraes, José Carlos Teixeira de Barros
Title in Portuguese
vMonGluco - sistema de monitoramento contínuo de glicose.
Keywords in Portuguese
Informática médica
Prontuário eletrônico do paciente
Redes sem fio
Sistemas de informação
Abstract in Portuguese
Pacientes críticos tratados em uma UTI comumente apresentam quadros severos de hiperglicemia. Estudos mostram que o controle da glicemia a níveis restritos leva à melhoria no prognóstico de tais pacientes. O controle glicêmico é feito através da medição freqüente da glicemia através de um exame de "ponta de dedo", aliada à infusão de insulina, numa atividade bastante trabalhosa para a equipe de enfermagem. Nos últimos anos, surgiram os primeiros sistemas comerciais de monitoramento contínuo de glicose para uso ambulatorial. Entretanto, há uma série de limitações que dificultam seu uso em uma UTI. No presente trabalho, foi desenvolvido um sistema de monitoramento contínuo de glicose para pacientes críticos hiperglicêmicos, batizado de vMonGluco. Esse sistema utiliza um monitor contínuo de glicose, disponível comercialmente, conectado a um palmtop, de forma a obter leituras de glicose em tempo real. Os dados coletados são enviados a um servidor seguindo a norma Health Level Seven (HL7). O servidor redireciona os dados a um monitor de beira de leito, disponibilizando as leituras de maneira prática. As informações também são armazenadas em um sistema de Prontuário Eletrônico do Paciente. Testes realizados em pacientes comprovaram a validade das leituras obtidas. Assim, com o presente trabalho, espera-se trazer uma contribuição prática e significativa no tratamento de pacientes críticos hiperglicêmicos.
Title in English
vMonGluco - Glucose continuos monitoring system.
Keywords in English
Electronic health record
Information systems
Medical informatics
Wireless nets
Abstract in English
Critical patients in an ICU usually experience severe hyperglycemia. Studies show that the control of glycemia to restricted levels can increase the prognosis of these patients. This control is usually done through the frequent reading of glycemia using a fingerstick test, together with the infusion of insulin, in a troublesome activity for the nursery team. In the last few years, the first commercial glucose monitoring systems for ambulatory use have been created. However, several difficulties limit its use in an ICU. In the present work, a continuous glucose monitoring system, named as vMonGluco, was developed. The system uses a commercially available continuous glucose monitor connected to a palmtop, in order to get glucose readings in real time. The collected data are sent to a server using the Health Level Seven (HL7) standard. The server redirects the data to a bedside monitor, so the readings can be accessed in practical way. The information is also stored in an Electronic Health Record system. Tests applied to patients showed the validity of the obtained readings. This way, with the present work, it is expected to bring a practical and significant contribution to the treatment of critical hyperglycemic patients.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-08-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.