Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2012.tde-26072013-171913
Document
Author
Full name
Jimmy Mauricio Valencia Rivas
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Moriya, Henrique Takachi (President)
Ferreira, Caroline Marcantonio
Moraes, José Carlos Teixeira de Barros
Title in Portuguese
Avaliação quasi-estática da mecânica respiratória em roedores utilizando insuflador pulmonar.
Keywords in Portuguese
Bioengenharia
Biomecânica
Modelos matemáticos
Roedores
Sistema respiratório
Abstract in Portuguese
A avaliação da mecânica respiratória (AMR) busca descrever o comportamento mecânico do sistema respiratório, para melhor entender a sua fisiologia e a sua patofisiologia. O método quasi-estático é caracterizado pela AMR em condições nas quais a aceleração dos tecidos pode ser considerada desprezível. Esta dissertação de mestrado teve como objetivo avaliar a mecânica respiratória pelo método quasi-estático em roedores, utilizando um insuflador pulmonar para pequenos roedores (IPPR) construído no Laboratório de Engenharia Biomédica (LEB) da Escola Politécnica da Universidade de São Paulo (EPUSP). Uma extensa revisão da literatura sobre fisiologia e técnicas de AMR em humanos e roedores é apresentada. Uma documentação bastante detalhada sobre a implementação e o funcionamento do IPPR é fornecida, com o intuito de permitir que o dispositivo seja reproduzido. Testes de bancada foram executados, para avaliar o funcionamento do IPPR, e um protocolo experimental com modelo animal de doença, em ratos Wistar envenenados por Paraquat, foi realizado. Os resultados dos testes de bancada mostraram que o equipamento ainda carece de alguns ajustes, pois apresenta erros na indicação de volume, da ordem de 5%, mas que podem ser compensados na análise dos dados experimentais obtidos. No futuro, pretende-se sanar essa imprecisão, tornando o IPPR independente de um microcomputador com sistema operacional multitarefa. Os resultados da aplicação do modelo matemático exponencial, nos dados obtidos de curvas pressão-volume no protocolo experimental, trouxeram informações que estão de acordo com as características observadas no modelo animal de envenenamento por Paraquat.
Title in English
Quasi-static assessment of the respiratory mechanics in rodents using a lung insufflator.
Keywords in English
Bioengineering
Biomechanics
Mathematical models
Respiratory system
Rodent
Abstract in English
The assessment of respiratory mechanics (AMR) aims to describe the mechanical behavior of the respiratory system in order to better understand its physiology and pathophysiology. The quasi-static method is characterized by the AMR under conditions where the tissue's acceleration can be considered negligible. The purpose of this master degree dissertation was to assess the respiratory mechanics by quasistatic method in rats using a lung insufflator for small rodents (IPPR) implemented in the Biomedical Engineering Laboratory (LEB) of Escola Politécnica of University of São Paulo (EPUSP). Abroad literature review on AMR techniques and on physiology in humans and rodents was presented. A fairly detailed documentation of the assembly and the operation of the IPPR was provided in order to allow the device to be reproduced. Bench tests were conducted to evaluate the behavior of the IPPR, and an animal disease model by Paraquat poisoning protocol was performed in Wistar rats. The bench tests results showed that the equipment still needs some tweaking, because it presents errors in volume indication of the order of 5%, but these errors can be compensated in the analysis of the experimental data. In the future, there is an intention to correct this inaccuracy turning the IPPR independent of a multitask microcomputer operating system. The results of the mathematical exponential modeling applied on the pressure-volume curves in the experimental protocol are in good agreement with the characteristics observed on Paraquat poisoning animal model.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-08-05
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • CIRELLI, M., et al. Sistema microcontrolado para estudos de curva pressão volume em pulmões de pequenos roedores. In XXII CONGRESSO BRASILEIRO DE ENGENHARIA BIOMÉDICA, Tiradentes, 2010. XXII CONGRESSO BRASILEIRO DE ENGENHARIA BIOMÉDICA., 2010.
  • MARTINEZ, D. M., et al. Comparison of two exogenous surfactants using a Langmuir film balance. In Biomedical Engineering Society Annual Meeting, Atlanta, 2012. BMES 2012 Annual Meeting.Atlanta : BMES, 2012. Abstract.
  • RIVAS, J. M. V., et al. MODELAJE EXPONENCIAL DE CURVAS PRESIÓN-VOLUMEN EN RATONES BAJO EL EFECTO DE PARAQUAT. In XXIII Congresso Brasileiro de Engenharia Biomédica, Ipojuca, 2012. XXIII Congresso Brasileiro de Engenharia Biomédica., 2012.