Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2010.tde-16082010-161914
Documento
Autor
Nombre completo
Roberto Castro Júnior
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Moraes, José Carlos Teixeira de Barros (Presidente)
Dib, Sérgio Atala
Gutierrez, Marco Antonio
Muhlen, Sérgio Santos
Pasqualucci, Silvia Helena Gelás Lage
Título en portugués
Glicosímetro de pulso
Palabras clave en portugués
Diagnóstico
Glicose (medição; instrumentos)
Resumen en portugués
Este trabalho descreve o desenvolvimento e a avaliação clínica de um instrumento para monitorização contínua e não-invasiva da concentração de glicose no sangue arterial adotando o mesmo método que a oximetria de pulso utiliza para determinação da saturação do sangue arterial. O sistema para medição de glicemia de pulso desenvolvido neste trabalho foi projetado a partir da utilização de um sensor óptico similar aos sensores de oximetria de pulso utilizando os comprimentos de onda de 805 e 1350 nm. Foi realizada uma avaliação clínica do instrumento com 20 voluntários masculinos e femininos entre 16 e 63 anos, de 48 a 112 kg e diferentes raças. Para estes voluntários, o instrumento apresentou uma exatidão (Arms) e desvio padrão (SDR) da ordem de 10 mg/dl, que podem ser considerados muito bons, quando comparado com monitores de glicemia do tipo ponta de dedo, que apresentam uma exatidão da leitura da ordem de 15 mg/dl para a faixa de medidas utilizada.
Título en inglés
Pulse glucometer.
Palabras clave en inglés
Diagnosis
Glucose (measurement; device)
Resumen en inglés
This paper describes the development and the clinical evaluation of a continuous non-invasive monitoring device for blood glucose concentration in arterial blood. The adopted method was the same one used in pulse oximetry for determining arterial blood saturation. The measurement system developed in this project to determine pulse blood glucose level was based on an optical sensor similar to the pulse oximetry sensors using wavelengths of 805 and 1350 nm. A clinical trial of the device was performed with 20 volunteers, both male and female, aged 16 to 63, weighting 48 to 112 kg and of different races. For this group of volunteers the device presented an accuracy (Arms) e standard deviation (SDR) in the magnitude of 10 mg/dl, considered very good when compared to blood glucose monitors of the fingertip type, which presents a reading accuracy in the magnitude of 15 mg/dl for the range of measurements employed.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-09-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.