• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2009.tde-11082010-163813
Document
Auteur
Nom complet
Mauricio Higa
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Gutierrez, Marco Antonio (Président)
Furuie, Sérgio Shiguemi
Pasqualucci, Silvia Helena Gelas Lage
Titre en portugais
Métodos para quantificação da artéria carótida em imagens de ultrassom modo-B e Doppler.
Mots-clés en portugais
Contornos ativos
Fluxo de sangue
Gráfico de velocidade do sangue
Integral de velocidade e tempo
Modelo matemático da artéria
Quantificação da artéria carótida
Ultrassonografia Doppler
Ultrassonografia modo-B
Resumé en portugais
No campo da medicina diagnóstica através de imagens, o baixo custo e a característica não-invasiva da ultrassonografia modo-B favoreceram as pesquisas que analisam a relação entre a espessura íntima-média (EIM) da artéria carótida e o desenvolvimento de doenças cardiovasculares. Outra técnica de ultrassonografia, baseada no efeito Doppler, também tem sido extensivamente empregada em ambientes clínicos para a medição da velocidade e do fluxo de sangue das artérias periféricas, oferecendo uma abordagem distinta para estudar as doenças cardiovasculares. Neste trabalho, métodos computacionais foram implementados e analisados para extrair informações quantitativas de artérias a partir de imagens 2D. Os ensaios com imagens em modo-B contemplaram a combinação de técnicas de filtragem e algoritmos de contornos ativos para a detecção das interfaces das paredes arteriais e medições da EIM e do diâmetro da luz (DL). Um modelo matemático e 7 imagens reais da artéria carótida comum foram utilizados neste estudo que, dentre as diversas combinações de filtros e algoritmos, apresentou resultados quantitativos similares no cálculo do DL. Para a EIM, porém, a reduzida dimensão da camada íntima-média proporcionou variações indesejadas dos cálculos. Para medir a velocidade do sangue utilizando o modo Doppler, um método semiautomático foi incorporado a um aplicativo computacional para a detecção da envoltória do espectro do gráfico de velocidades. Uma análise comparativa entre sistemas de ultrassonografia comerciais operados por especialistas e este aplicativo incluiu a velocidade de pico sistólico e a integral de velocidade e tempo (VTI) das artérias carótida comum e braquial e de exames ecocardiográficos. A análise de Bland-Altman e o coeficiente de correlação validaram esta metodologia que, complementada pela interface gráfica amigável do aplicativo, pode auxiliar os clínicos em seus estudos de larga escala, baseados nas imagens Doppler ultrassonográficas, com as seguintes vantagens: redução do tempo operacional e de resultados subjetivos e aumento do grau de reprodutibilidade dos resultados.
Titre en anglais
Methods for quantification of the carotid artery in B-mode and Doppler ultrasound images.
Mots-clés en anglais
Active contour
B-mode ultrasound
Blood flow
Blood velocity
Carotid artery quantification
Doppler ultrasound
Mathematical model of the artery
Velocitytime integral
Resumé en anglais
In the field of image-based diagnostic medicine, low cost and noninvasive B-mode ultrasound technique have supported the researches which investigates the relation between the carotid intima-media thickness (IMT) and the development of cardiovascular diseases. Other ultrasound technique, that offers a different approach to study these diseases, is based on Doppler effect and has also been extensively used in clinical sites to measure blood velocity and flow in peripheral arteries. In this work, computational methods were implemented and analyzed to extract quantitative data from 2D images of arteries. Tests with B-mode images covered the combination of filtering techniques and active contour algorithms, in order to detect the arterial wall interfaces and to measure IMT and lumen diameter (LD). One mathematical model and seven real images of the common carotid artery were used in this study which, among several filters and algorithms combinations, showed similar quantitative results for DL measurements. However, for IMT, the small thickness of intima-media layer led to undesirable variation results. To measure blood velocity by using Doppler mode, a semi-automatic methodology was implemented in a computational tool to detect the spectrum envelope of the velocity graphic. A comparative analysis between commercial ultrasound systems operated by specialists and this tool included systolic peak velocities and velocity-time integral (VTI) of the common carotid and brachial arteries and of echocardiographic exams. Bland-Altmans analysis and the correlation coefficient validated this methodology which, besides the user friendly graphical interface of the tool, may help the clinicians for their large-scale studies based on Doppler ultrasound images, with the following advantages: to save operational time, to lower subjective results, and to support measurement reproducibility.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-10
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.