Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2017.tde-05102017-091731
Documento
Autor
Nombre completo
Henrique Takachi Moriya
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1999
Director
Tribunal
Moraes, Jose Carlos Teixeira de Barros (Presidente)
Cestari, Idágene Aparecida
Negrão, Carlos Eduardo
Título en portugués
Avaliação de transdutores para análise metabólica humana.
Palabras clave en portugués
Análise metabólica humana
Bioengenharia
Dióxido de carbono
Instrumentação biomédica
Oxigênio
Sistema respiratório
Transdutores fluxo
Resumen en portugués
A calorimetria indireta para análise do metabolismo humano tem se mostrado um método não invasivo de crescente importância no estudo mais preciso das respostas metabólicas e cardio-respiratórias. Entretanto, o alto custo dos equipamentos aliado à falta de conhecimento das técnicas tem impedido a disseminação do uso de analisadores metabólicos no Brasil. Este trabalho foi desenvolvido com o intuito de oferecer uma visão global dos procedimentos de calorimetria indireta aplicados à avaliação do metabolismo humano sob a abordagem de Engenharia Biomédica. Foram avaliados três transdutores tipicamente utilizados em equipamentos de calorimetria indireta para análise metabólica humana: um transdutor eletroquímico de oxigênio, um transdutor de dióxido de carbono por radiação infravermelha e um transdutor de fluxo em volume tipo turbina. O transdutor de oxigênio mostrou-se bastante confiável, mas com um tempo de resposta bastante elevado para aplicações em análises de respiração a respiração. A principal deficiência do transdutor de dióxido de carbono está no fato de sua configuração proporcionar um aumento significativo na resistência à respiração do indivíduo. Verificou-se que o transdutor de fluxo em volume apresenta um melhor comportamento para um fluxo em torno de 20 litros/minuto. Apesar das limitações apresentadas pelos transdutores, os resultados dos ensaios foram úteis e representativos para a compreensão do funcionamento de um analisador metabólico humano porcalorimetria indireta, evidenciando quais deficiências devem ser sanadas em pesquisas futuras e os cuidados a serem considerados na implantação do laboratório para análise metabólica/respiratória sendo instalado no Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
Título en inglés
Assessment of transducers to human metabolic analysis.
Palabras clave en inglés
Biomedical instrumentation
Carbon dioxide
Flow
Human metabolic analysis
Oxygen
Transducers
Resumen en inglés
The indirect calorimetry for analysis of the human metabolism has been a no invasive method of increasing importance in the study of metabolic and cardiorespiratory responses. However, the high cost of the equipment ally to the lack of knowledge of the techniques have been obstacles to the use of metabolic analysers in Brazil. This research was developed with the intention to offer a global vision of the applied procedures of indirect calorimetry to the evaluation of the human metabolism under the prism of the Biomedical Engineering. Three transducers typically used in equipment of indirect calorimetry for metabolic analysis had been evaluated: an electrochemical transducer of oxygen, a carbon dioxide transducer by infrared absorption and a turbine flowmeter. The oxygen transducer revealed sufficiently trustworthy, but a too high response time for applications in breath by breath analyses. The main deficiency of the transducer of carbon dioxide is to provide a significant increase in the flow resistance. It was verified that the flowmeter presents one better behavior for a stream around 20 litres/minute. Despite the limitations presented for the transducers, the results of the assays had been useful and representative for the understanding of the functioning of a human metabolic analyser for indirect calorimetry, evidencing which points have to be improved in future researches and to be considered in the implantation of the laboratory for metabolic and respiratory analysis being installed in the Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.